TELECOM INTERFACE

The dialler facility on this controller has been designed to provide optimum flexibility in the way in which alarm events
are reported. This flexibility includes options for reporting to a central monitoring station using Contact ID format, a
Domestic reporting option using alternating siren tones, a format for reporting alarms to an alpha numeric pager and a
powerful Speech Dialler.
In accordance with the statutory requirements of the Telepermit standards we must bring the following points to your
attention; A readily accessible disconnect device shall be incorporated into the 230V fixed wiring. In the event of any
problem with this device, the by-pass switch should be operated. The user is to then arrange with the installer of the
device to make the necessary repairs. Should the matter be reported to Telecom as a wiring fault, and the fault be
proven to be due to the alarm panel, a call out charge will be incurred.
Should the control panel require relocation the Telecom connection must be disconnected before the power is
disconnected. Similarly when reconnecting the dialler, it is necessary to power up the panel before connecting the
dialler to the Telecom Network.
Connection to the Telecom network should be made in accordance with Access Standards Newsletter #65 dated
November 1993. This connection is to be readily accessible to allow disconnection in the event of a fault. An example
of this connection method is shown below.
NOTE: The telephone line must not enter the cabinet through the same cable entry hole as any 230 volt mains cables. A
separate cable entry must be used for 230 volt cabling
When using one of the knock-outs around the side of the cabinet for supply entry, a suitable bushing must be used
where the supply cables pass through a knock-out.
The transmit level from this device is set at a fixed level and because of this there may be circumstances where this
device does not give its optimum performance. Before reporting such occurrences as faults, please check the line with a
standard Telepermitted telephone, and do not report a fault unless the telephone performance is impaired.
This automatic dialling equipment shall not be set up to make calls to the
Emergency Number 000
115