Pendant Arm/Disarm/Stay Mode Arm/Disarm Chirp To Output - Assa Abloy S series Installation & Programming Manual

8/16 zone control communicator
Table of Contents

Advertisement

AREA STAY ARM INDICATION to OUTPUT
AREA STAY ARM INDICATION to OUTPUT - P48E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
For monitoring purposes a Stay Arm indication can be assigned to an Output. Each Area can have a separate
indication assigned to a different output if required.
AREA DISARM INDICATION to OUTPUT - P49E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
For monitoring purposes a Disarm indication can be assigned to an Output. Each Area can have a separate disarm
indication assigned to a different output if required.
PENDANT ARM CHIRP to OUTPUT - P50E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
When Arming the alarm using a Radio Key it is necessary to have some form of Arm indication. This can done by
pulsing an Output once when the area is armed (one chirp). The Chirp is linked to the pulse time (P39E) for the
output concerned. If Output 1 or 2 are used for the chirp and a horn speaker is connected to the output (see P37E1 or
2E option 1), the siren on the output will give a single tone for the chirp instead of the swept tone used for alarms.
Also Arming via an Access Tag/Card can generate the Chirp if option 4 is On at P47E.
PENDANT STAY MODE ARM CHIRP to OUTPUT
PENDANT STAY MODE ARM CHIRP to OUTPUT - P51E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
When Arming Stay Mode using a Radio Key it is necessary to have some form of Arm indication. This can done by
pulsing an Output once when the area is armed (one chirp). The Chirp is linked to the pulse time (P39E) for the
output concerned. If Output 1 or 2 are used for the chirp and a horn speaker is connected to the output (see P37E1 or
2E option 1), the siren on the output will give a single tone for the chirp instead of the swept tone used for alarms.
Also Stay Arming via an Access Tag/Card can generate the Chirp if option 4 is On at P47E.
PENDANT DISARM CHIRP to OUTPUT - P52E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
When Disarming the alarm using a Radio Key it is necessary to have some form of Disarm indication. This can done by
pulsing an Output twice when the area is disarmed (two chirps). The Chirps are linked to the pulse time (P39E) for the
output concerned. If Output 1 or 2 are used for the chirp and a horn speaker is connected to the output (see P37E1 or
2E option 1), the siren on the output will give a single tone for the chirp instead of the swept tone used for alarms.
Also Disarming via an Access Tag/Card can generate the Chirp if option 4 is On at P47E.
AREA DISARM INDICATION to OUTPUT
PENDANT ARM CHIRP to OUTPUT
PENDANT DISARM CHIRP to OUTPUT
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8