TEMPORARY OUTPUT DISABLE - P25E 9E (Select output # 1-8)
This address allows a technician to select any output/s to be temporarily disabled for one alarm or armed cycle, eg by
selecting LEDS 1-4 (Outputs 1-4) at this location then leaving program mode, outputs 1-4 will not turn on following
any alarms. The technician is now free to arm the system to test all monitoring signals without having any internal
and/or external alarms activating. When the alarm is reset or disarmed all outputs will now work normally again.
MISCELLANEOUS PANEL OPTIONS - P25E 10E
Option 1 - Panel Tamper is 2k2 EOL
Option 2 - Direct access to program mode for the Installer Code
Option 3 - Disable Mains Fail Test
Option 4 - Listen-in to O/P # 1 Low Volume
Option 5 - Receiver Fail/RF Jammed Lockout
Option 6 - Send Output information to Keypad Buss
Option 7 - Cannot arm if the system battery is low.
Option 8 - Installer Lockout
Option 1
Panel Tamper is 2k2 EOL - The Tamper input (Tmp) on the control panel requires either a short circuit
or a 2k2 End-of-Line resistor. If option 1 is on the panel must see a 2k2 resistor (EOL) across the Tmp &
0V terminals to ensure the tamper is sealed. If this option is turned off then a simple short circuit is all
that is required to seal the panel tamper.
Option 2
Direct access to program mode for the Installer Code - If this option is on, the Installer Code can gain
access to Installer Program Mode directly. If the option is turned off, the installer can only gain access to
Installer Program Mode via Client Program Mode. This option allows the owner to control program
mode access by the installer. The User must have option 3 at location P5E turned on for them to allow
installer access.
Option 3
Disable Mains Fail Test - If the panel must be run off a DC supply or the Mains supply can fail regularly,
this option disables the mains voltage monitoring to prevent mains fail alarms from occurring.
Option 4
Listen-in to O/P # 1 Low Volume - If Listen-In to Output 1 is turned on (P175E8E), the level of sound
from the speaker can be controlled with this option. If this option is Off the sound level during listen-in
to O/P 1 is high volume, turning this option On makes the sound level low volume. For listen-in to
Output 1 to work the device connected to O/P 1 must be an 8Ώ speaker and the output must be
modulated (P35E1E Option 1 on). Failure to do this could result in damage to the speaker & output.
Option 5
Receiver Fail/RF Jammed Lockout - If the receiver fail delay (P25E7E) is set to a value other than 0 and
the panel sees no activity from the receiver for the set period of time, a receiver fail alarm will be
generated. If this option is turned on, the panel cannot be armed until the cause of the receiver failure
has been resolved. Also if the receiver detects a continuous signal for longer than 60 seconds it will send
an RF Jammed signal to the control panel. Under this alarm condition and if this option is turned on, the
control panel cannot be armed until the interference has been removed.
Option 6
Send Output information to Keypad Buss - There is an optional 4 x relay output expander board that
can be connected to the keypad buss if required. For this output expander to work option 6 must be
turned on for the data to be sent on the keypad buss to the expander.
Option 7
Cannot arm if the system battery is low. - If this option is turned on, the panel cannot be armed if the
panel battery is low. When the battery is fully charged the panel can then be armed. If this option is
turned off the panel can be armed during these fault conditions.
Option 8
Installer Lockout - Normally if the panel is powered up with the panel tamper open (ie system tamper
alarm active) and in the Disarm state, then the panel will go into installer program mode when the
<PROGRAM> then <ENTER> buttons are pressed. If this option is on, the panel will not allow access to
program mode on power-up and the only valid method of accessing program mode is via the installer
code.

TEMPORARY OUTPUT DISABLE

MISCELLANEOUS PANEL OPTIONS

46