Option 1
Area "A" - This option assigns the keypad <A> button to Area A. If a keypad <A> button is assigned to only
Area A it can only Arm or Disarm that area.
Option 1
Area "B" - This option assigns the keypad <A> button to Area B. If a keypad <A> button is assigned to only
Area B it can only Arm or Disarm that area.
KEYPAD <A> BUTTON AREA OPTIONS - P79E 1-8E (APPLIES TO PORTRAIT LCD KEYPAD ONLY)
Option 1 - <A> button can Arm
Option 2 - <A> button can Arm Stay Mode
Option 3 - <A> button can Disarm at All Times
Option 4 - <A> button can Disarm Stay Mode at All Times
Option 5 - <A> button can Reset Alarms
Option 6 - <A> button can Arm Latchkey Mode
Option 7 - <A> button can Disarm During Exit Delay
Option 8 - <A> button can Disarm Stay Mode During Exit Delay
Option 1
<A> button can Arm - This option enables single button Arming using the <A> button. For single button
operation to work options 2 & 3 must be off at location P46E.
Option 2
<A> button can Arm Stay Mode - This option enables single button Arming of Stay Mode using the <A>
button. For single button operation to work options 2 & 3 must be off at location P46E.
(NOTE: Following arming of Stay Mode, if the <ENTER> button is pressed, all entry & exit delays will be
reset to zero for that armed period).
Option 3
<A> button can Disarm at All Times - This option enables single button Disarming using the <A> button.
For single button disarm operation to work options 2 & 3 must be off at location P46E
Option 4
<A> button can Disarm Stay Mode at All Times - This option enables single button Disarming of Stay Mode
using the <A> button. For single button disarm operation to work options 2 & 3 must be off at location
P46E
Option 5
<A> button can Reset Alarms - If this option is On, Pressing the <A> button (provided Option 3 is also On)
will reset an alarm condition without having to enter a user code.
Option 6
<A> button can Arm Latchkey Mode - This option enables single button Arming of the alarm in Latchkey
report mode using the <A> button. For single button Arm operation to work options 2 & 3 must be off at
location P45E. When Latchkey Mode is set on Arming, any code without the Latchkey option (P4E Option 6)
used to Disarm the Alarm will cause a Disarm report to be sent via the dialler.
Option 7
<A> button can Disarm During Exit Delay - This option allows single button Disarming using the <A>
button provided the Armed Mode exit delay is active. If the exit delay has expired the <A> button cannot be
used to disarm the alarm. For single button disarm operation to work options 2 & 3 must be off at location
P46E
Option 8
<A> button can Disarm Stay Mode During Exit Delay - This option allows single button Disarming of Stay
Mode using the <A> button provided the Stay Mode exit delay is active. If the Stay Mode exit delay has
expired the <A> button cannot be used to disarm Stay Mode. For single button disarm operation to work
options 2 & 3 must be off at location P46E
KEYPAD <B> BUTTON AREA ASSIGNMENT
KEYPAD <B> BUTTON AREA ASSIGNMENT - P80E 1-8E (APPLIES TO PORTRAIT LCD KEYPAD ONLY)
Option 1 - Area "A"
Option 2 - Area "B"
Option 1
Area "A" - This option assigns the keypad <B> button to Area A. If a keypad <B> button is assigned to only
Area A it can only Arm or Disarm that area.
Option 1
Area "B" - This option assigns the keypad <B> button to Area B. If a keypad <B> button is assigned to only
Area B it can only Arm or Disarm that area.