Option 6
4 + 2 (10 pps) - This option transmits a 4 digit account code followed by a 2 digit event code to a central
monitoring station. The handshake tone from the monitoring station must be 2300hz and the transmit tone
from the panel will be at 1800hz at 10 pulses per second.
Option 7
4 + 2 (20 pps) - This option transmits a 4 digit account code followed by a 2 digit event code to a central
monitoring station. The handshake tone from the monitoring station must be 1400hz and the transmit tone
from the panel will be at 1900hz at 20 pulses per second.
Option 8
4 + 2 (20 pps) - This option transmits a 4 digit account code followed by a 2 digit event code to a central
LED KEYPAD
LED KEYPAD
BUTTON
INDICATION
"BYPASS"
-
"PANIC"
11
"MEMORY"
12
"CONTROL"
13
"ARM"
14
"STAY"
15
monitoring station. The handshake tone from the monitoring station must be 2300hz and the transmit tone
from the panel will be at 1800hz at 20 pulses per second
Option 9
4 + 2 (DTMF) - This option transmits a 4 digit account code followed by a 2 digit event code plus a
checksum using DTMF signals to a central monitoring station. The handshake tone from the monitoring
station must be 1400 hz /2300 hz .
Option 10
SIA - This option selects FSK SIA format. If using SIA format, ensure that the monitoring receiver does not
generate a 4+2 2300hz acknowledge tone before the SIA acknowledge tone because the 4+2 tone accuracy
is +/– 5% which can make it the same as the SIA acknowledge tone. Also when reporting alarms on different
areas (1 =Area A and 2 = Area B) the panel will send the area number associated with each event (ri01 or
ri02) but it will also send different account codes if programmed that way. To avoid using two account
numbers when reporting alarms on different areas you should program both account codes (P62E 1 & 2) to
be the same number and identifying the two areas by the area number sent.
Option 11
SIA Slow - This option selects FSK SIA Slow format. This format is similar to option 10 except every signal will
be sent separately with a kissoff after each signal whereas option 10 will send all signals in one continuous
burst with one kissoff at the end. In SIA slow the area number is not sent (see option 10 above) so each
account code must be different when identifying alarms for both areas.
TELEPHONE NUMBER REPORT OPTIONS - P183E 1-8E
Option 1 - Stop Dialling if Kissed Off
Option 2 - Monitor Call Progress
Option 3 - Blind Dial
Option 4 - Use Group Numbers for Contact ID Reporting
Option 5 - Stay On-line after Alarm report for two way voice
Option 6 - Auto Kiss-off for Voice/Domestic Reporting
Option 7 - Use the Dial Pre-fix Number
Option 8 - Used as the Call-back Number
Option 1
Stop if Kissed Off - If this option is turned on for the telephone number, the dialler will stop sending the
alarm if the signal is kissed off and will not proceed with any other telephone numbers for that event. If not
kissed off the dialler will start dialling any other programmed numbers. If the event is not kissed off from any
of the telephone numbers and the maximum re-tries limit is reached then the event is marked as unsent
and will be added to the next event that causes the dialler to report. If this option is off, the dialler will send
LCD KEYPAD
BUTTON
CONTROL & 0
CONTROL & 2
CONTROL & 3
CONTROL & 4
CONTROL & 5
CONTROL & 6

TELEPHONE NUMBER REPORT OPTIONS

LCD KEYPAD
LCD KEYPAD
CID & 4+2
TELEPHONE INDI-
INDICATIONS
CATIONS
-
DELETE #
B
#
C
*
D
-
E
w
F
=
83
CID & 4+2
TELEPHONE NUMBER
SPECIAL
SPECIAL FUNCTION
CHARACTERS
DELETE #
DELETE #
"B"
"#"
"C"
"*"
"D"
"2.5 sec Pause"
"E"
"Wait for 2nd Dial-tone"
"F"
"5 sec Pause"