METERS AND GAUGES
- Service Adjustment
Procedures
-
16Y283:
Point F
/ /
Point E
16Y2874
16Y2835
OIL PRESSURE GAUGE SIMPLE TEST
NOBHIFB
I.
Disconnect
the
wiring
connector
from
the
oil pressure
--
gauge
unit inside the engine
compartment.
2.
Ground
the connector
at the harness
through
a
test
light.
i
3.
Turn the ignition
key to the ON position.
4.
Check to be surethat
the test light flashes or lights steadily
and the oil pressure
gauge
operates.
5.
If both the test light and
gauge
operate,
the circuit to the
gauge
unit is normal
and the
gauge
unit itself is faulty.
If the test light flashes
or lights steadily
but the gauge does
not operate,
the
gauge
is-faulty.
If neither
the test
light
nor the gauge
operates,
the oil
I
pressure
gauge
crrcuit IS faulty.
VOLTMETER INSPECTION
NOBHIGE
'I. Connect
the (+I termrnal
of the checking
voltmeter
to the S
termrnal
of the alternator-and
ground
the
(-1 termrnal.-
2.
Crank the engine and compare
rndrcatrons
to check that the
1
error IS wrthrn
the standard
value.
Standard
value:
at 12.5 V
&IV
FUEL GAUGE UNIT INSPECTION
NOBHIIE
To inspect the fuel gauge
unit, replace the unit from fuel tank.
_
FUEL GAUGE
UNIT
FLOAT
POSITION
CHECK
Move the float and measure
the float position
at points "F" and
"E"
when
the float arm contacts
the stopper.
Standard
value:
POINT
F: 34.4 - 38.2
mm
(1.35 - 1.50 in.)
POINT
E: 234 - 238 mm
(9.21
- 9.37
in.)
FUEL GAUGE
UNIT
RESISTANCE
CHECK
1. Check
that the resistance-between
terminals
2 and 3 ;is
LF
within
the standard
value when
the fuel gauge
unit float
is
-
between
positions
"F"
and
"E".
Standard
value:
Point
"F":
1 - 5 IZ
Point
"E":
103 - 117 11
2. Also check thatthe
resistance
changes
smoothly
Ehen
the
~-_
float is moved
to "F"
and "E".