Firmware Rewriting; Updating Method - Konica Minolta bizhub C350 Service Manual

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

Firmware upgrade
3.2

Firmware rewriting

• The F/W is updated using the Compact flash.
3.2.1

Updating method

NOTE
• NEVER remove or insert the Compact Flash card with the machine power turned
ON.
[2]
[1]
[3]
7. Press the Start key. (At this time, the Start key starts blinking red.)
8. Check that the Touch Panel shows the message indicating that the data has been
rewritten correctly ("Downloading Completed"). Check also the Check Sum value
("Check Sum XXXX") shown on the Touch Panel. (The Start key blinks green.)
9. Unplug the power cord from the power outlet.
NOTE
• Do not turn OFF the Power Switch.
10. Remove the Compact Flash card from the slot.
11. Turn OFF the Power Switch.
12. Plug the power cord and turn ON the Power Switch.
13. Call the Tech. Rep. mode to the screen.
14. Select ROM Version.
15. Make sure if the version of Firmware is updated.
2-34
bizhub C350 Field Service Ver2.0 Sep. 2004
1. With the Power Switch in the OFF
position, unplug the power cord from
the power outlet.
2. Remove one screw [1] and the metal
Blanking Plate [2].
4036fs2602c0
3. Insert the Compact Flash card into
the slot.
4036fs2603c0
4. Plug the power cord into the power
outlet and turn ON the Power Switch.
5. Six different types of F/W appear on
the Touch Panel.
6. Select the particular type of F/W to
be updated.
4036fs2604c0

Advertisement

Table of Contents
loading

Table of Contents