Konica Minolta bizhub C350 Service Manual page 207

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

TECH. REP. MODE
(2) Mail check
Functions
• To set whether or not to use Mail Check and the time interval for the POP3
Use
• To select not to use Mail Check
• To change the time interval for Mail Check
Setting/Procedure • The default setting is 15 min.
(3) Connection timeout
Functions
• To set the timeout period for connection during reception
Use
• To change the timeout period for connection during reception
Setting/Procedure • The default setting is 60 sec.
C. Send
• These are the settings for the Send used in the Remote Diagnosis System for the stan-
dard controller.
(1) SMTP server
Functions
• To set the SMTP server address for transmission used for the Remote Diagnosis
Use
• To set the address of the SMTP Server
Setting/Procedure • IP Address Version 4 format
[0 to 255]. [0 to 255]. [0 to 255]. [0 to 255]
(2) SMTP port number
Functions
• To set the SMTP port number for transmission used for the Remote Diagnosis
Use
• To set the Port Number of the SMTP Server
Setting/Procedure • The default setting is 25.
(3) Timeout of SMTP Server
Functions
• To set the timeout period for transmission
Use
• To change the timeout period for connection during transmission
Setting/Procedure • The default setting is 60 sec.
3-72
server used for the Remote Diagnosis System for the standard controller
15 min.
(1 to 120 min., No)
60 sec.
(30 to 300 sec.)
System for the standard controller
System for the standard controller
25
(1 to 65535)
60 sec.
(30 to 300 sec.)
bizhub C350 Field Service Ver2.0 Sep. 2004

Advertisement

Table of Contents
loading