Ccd Unit - Konica Minolta bizhub C350 Service Manual

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

Other
4.3.11

CCD Unit

[1]
[5]
[3]
2. Reinstall the Original Glass.
3. Turn ON the Power Switch.
4. Carry out the adjustment procedure for CD-Mag. If the specifications are not met,
loosen the CCD Unit mounting screws and move the CCD Unit in the FD direction as
necessary.
☞ 3-46
NOTE
• Hold the CCD Unit by hand when moving it. NEVER use a screwdriver or similar
tool to tap to move it, as a varied distance between the CCD sensor and lens
results.
2-46
bizhub C350 Field Service Ver2.0 Sep. 2004
[2]
4036fs2613c0
[3]
[4]
4036fs2510c1
4036fs2052c1
A. Removal Procedure
1. Remove the Original Glass.
☞ 2-43
2. Remove seven Screws [1], and
remove the CCD Unit Cover [2].
3. Remove four Screws [3] and Flat
Cable [4], and remove the CCD Unit
[5].
B. Reinstallation Procedure
1. Align the CCD Unit with the center of
the graduations as illustrated on the
left and then tighten the four screws.

Advertisement

Table of Contents
loading