Konica Minolta bizhub C350 Service Manual page 264

Hide thumbs Also See for bizhub C350:
Table of Contents

Advertisement

bizhub C350 Field Service Ver2.0 Sep. 2004
Code
C0040 Suction Fan Motor's failure to turn
C0046 Fusing Cooling Fan Motor/1 failure
to turn
C0048 Fusing Cooling Fan Motor/1 or Fus-
ing Cooling Fan Motor/2 failure to
turn
C004C Ozone Ventilation Fan Motor's fail-
ure to turn
C004D Toner Suction Fan Motor's failure to
turn
C004E Power Supply Cooling Fan Motor's
failure to turn
C004F Cooling Fan Motor 2's failure to turn
C0060 Fusing Drive Motor's failure to turn
C0061 Fusing Drive Motor turning at
abnormal timing
C0094 2nd Image Transfer Roller pres-
sure/retraction failure
C0096 Image Transfer Belt pressure/
retraction failure
C0098 Fusing Pressure Roller pressure/
retraction failure
Item
The Fan Lock signal remains HIGH for a prede-
termined continuous period of time while the
Motor remains stationary.
• The Motor Lock signal remains LOW for a predeter-
mined continuous period of time while the Motor
remains stationary.
• The 2nd Image Transfer Pressure Position Sensor is
not activated (retracted position) within 2 sec. after the
2nd Image Transfer Pressure/Retraction Motor has
started turning during a sequence of the 2nd Image
Transfer Roller's retracting motion.
• The 2nd Image Transfer Pressure Position Sensor is
not deactivated (pressed position) within 2 sec. after
the 2nd Image Transfer Pressure/Retraction Motor has
started turning during a sequence of the 2nd Image
Transfer Roller's pressing motion.
• The 1st Image Transfer Retraction Position Sensor is
not activated (retracted position) within 5 sec. after the
1st Image Transfer Pressure/Retraction Motor has
started turning during a sequence of the Transfer
Belt's retracting motion.
• The 1st Image Transfer Retraction Position Sensor is
not deactivated (pressed position) within 1 sec. after
the 1st Image Transfer Pressure/Retraction Motor has
started turning during a sequence of the Transfer
Belt's pressing motion.
• No change is observed in the encoder sensor pulse
even after the lapse of 0.5 sec. after the Fusing Pres-
sure/Retraction Motor has started turning for a
sequence of the Fusing Pressure Roller's retracting
motion.
• No change is observed in the encoder sensor pulse
even after the lapse of 0.5 sec. after the Fusing Pres-
sure/Retraction Motor has started turning for a
sequence of the Fusing Pressure Roller's pressing
motion.
• The Fusing Pressure Position Sensor is not activated
(pressed position) even when 30 encoder sensor
pulses are counted after the Fusing Pressure/Retrac-
tion Motor has started turning for a sequence of the
Fusing Pressure Roller's pressing motion.
Malfunction code
Description
4-19

Advertisement

Table of Contents
loading

Table of Contents