PC-401 Field Service Ver2.0 Sep. 2004
Code
C0996
LCT Lock Release Failure
C0997
LCT Shift Gate Operation Failure • The Shift Gate Home Position Sensor (PC14-LCT) can-
C0998
LCT Shift Failure
C099C
LCT Shift Motor Failure
C099D
LCT communication error
2.2.1

How to reset

• Press the Trouble Reset Switch on the Tech. Rep. Setting Switches Board to reset the
following malfunctions: scanner-related malfunctions, fusing-related malfunctions, expo-
sure lamp-related malfunctions and C3FFF.
• For any other malfunctions, open and close the Front Door or turn OFF and ON the
Power Switch.
Item
• The drawer cannot be determined to be out of position
even after the set period of time has elapsed after the
Tray Lock Solenoid (SL1-LCT) is energized after the
lowering operation is finished.
not be set to L even after the set period of time has
elapsed after the operation of the Shift Gate Motor (M3-
LCT) began with the Shift Gate Home Position Sensor
(PC14-LCT) set to L.
• The Shifter Return Position Sensor (PC11-LCT) is not
blocked even after the set period of time has elapsed
after the shift operation began (shift to the right).
• The Shifter Return Position Sensor (PC11-LCT) is not
blocked even after the set pulse is detected by the Shift
Motor Pulse Sensor (PC8-LCT) after the shift operation
began (shift to the right).
• The Shifter Home Position Sensor (PC12-LCT) is not
unblocked even after the set pulse is detected by the
Shift Motor Pulse Sensor (PC8-LCT) after the shift
operation began (shift to the right).
• The Shifter Home Position Sensor (PC12-LCT) is not
blocked even after the set period of time has elapsed
after the return operation began (shift to the left).
• The Shifter Home Position Sensor (PC12-LCT) is not
blocked even after the set pulse is detected by the Shift
Motor Pulse Sensor (PC8-LCT) after the return opera-
tion began (shift to the left).
• The Shifter Return Position Sensor (PC11-LCT) is not
unblocked even after the set pulse is detected by the
Shift Motor Pulse Sensor (PC8-LCT) after the return
operation began (shift to the left).
• The Shift Motor Pulse Sensor (PC8-LCT) cannot detect
both edges of H/L even after the set period of time has
elapsed while the Shift Motor (M4-LCT) is turning back-
ward/forward (raise/lower).
• Due to a software malfunction, etc., the time on the
watchdog timer has run out and a reset is performed.
Trouble code
Description
4-5