Board switch
7.2.1
Initialize Procedure
1. Turn OFF the Power Switch.
2. With the circuit across pins of PJ2 closed, turn ON the Power Switch.
3. In about 5 sec., open the PJ2 circuit.
4. Check that the message "Initialize Completed" is displayed on the Touch Panel and
then touch "END."
7.2.2
Memory Clear Procedure
1
1. Call the Tech. Rep. Mode to the screen.
☞ 3-40
2. Press the following keys in this order: Stop → 9
3. Security Mode menu will appear.
4. Press the following keys in this order: Stop → 0 → Stop → 1
5. Touch the "Memory Clear" key.
6. Touch the "Enable" key and touch the "OK" key.
7.2.3
If the machine exhibits an erratic display or operation.
1. Turn OFF and ON the Power Switch.
1. Unplug and plug in the power cord.
2. Initialize the machine.
3. Memory Clear the machine.
• Do not perform Memory Clear casually, as it clears the types of data mentioned
above. If Memory Clear has been performed, be sure to make settings for the func-
tions that have been cleared once again.
7.2.4
Data/Conditions Cleared by Reset Switches/Pins
Data Cleared
Misfeed display
Fusing
Optical
Malfunction
Scanner
display
C3FFX
Others
Erratic operation/display
Utility Mode
(Store, User's Choice:1, 2, Admin. Code)
Tech. Rep. Mode
(System Input)
Security Mode
(Counter Setting)
Touch Panel Correction Mode
❍: Cleared
—: Not cleared
3-108
Clearing Method
Front Door
Open/Close
❍
—
❍
—
—
—
—
—
bizhub C350 Field Service Ver2.0 Sep. 2004
Trouble
Initialize
Reset Switch
—
❍
❍
❍
—
—
—
—
Memory