7.2 RS232C HIGH SPEED SERIAL INTERFACE (cont'd)
Notes:
Check the setting seal of the serial interface card.
The correct settings may vary depending on the type and revision of the board.
The setting range of baud rate and protocol can be changed in the printer's Interface Mode. See Section
3.7 [Operation and Configuration] for details.
Any communication settings (e.g. Multi/1 item buffer) not controlled by the DIP switches can be set in the
printer's Interface Mode (See Section 3.7) using the operation panel.

7.2.2 Basic Specifications

Synchro system
Maximum receive
buffer
capacity
Code
Connector
Transmission form
Signal levels
DR308e Operator's Manual
Asynchronous method
2.95MB
0MB
Near full
occurred
Near full
released
ASCII (7 bits) Graphic (8 bits)
Printer side
DB-25S (female) or equivalent
Cable side
DB-25P (male) or equivalent
Cable length
5m (16ft) or less
Start b1
b2
b3
[Note] When using 7bits, b8 will be omitted.
High level
: +5 to +12V
Low level
: -5 to -12V
13
25
Serial Connector Pin Asignments
b4
b5
b6
b7
b8