Appliance Preparation; Installation To Fireplace - Valor Dream Fireslid 9500433 Installer's Manual

Inset live fuel effect gas fire with either
Table of Contents

Advertisement

Valor 600B610_01
7/12/00
Appliance Preperation
4.2.
Disconnect the control linkage from the
4.2.1
burner unit by removing the shouldered
screw which joins the control linking bar
to the control pivot unit (see figure 7).
figure 7
Control linkage
Detach the burner unit from the
4.2.2
convection box by removing two screws
(see figure 8). Lift the burner unit clear.
figure 8
Burner attatchment points
Fit the coal rear support to the burner by
4.2.3
inserting the support through the slot
in the burner tray from the underside.
Align the fixing holes and fasten with the
two tapping screws supplied in the
direction of the arrows in figure 9.
figure 9
Coal rear support fitting
Self-adhesive foam seals are supplied for
4.2.4
attaching to the rear of the firebox frame
on all three faces. Make sure that all joints
are butted together to prevent air gaps.
3:22 PM
Page 8
INSTALLER GUIDE

5.INSTALLATION TO FIREPLACE

5.1
5.2
5.3
5.4
5.5
5.6
Page 8
Cables and eyebolts are supplied for the
retention of the appliance. Ensure that
the interior of the fireplace is sufficiently
sound to take the eyebolts and wall plugs.
If the fixing areas have deteriorated due to
prolonged use, they should be made
sound with a suitable cement.
Drill two holes in the rear wall of the
fireplace for the eyebolt plugs. The holes
should be drilled in the positions shown
in figure 10 using a no.12 masonry drill.
The holes should be equidistant each side
of the centre line of the fireplace to ensure
that the appliance finishes centrally in the
opening when tension is applied to the
cables.
Insert a fibre plug into each hole. Use the
rawlplugs supplied with this appliance -
Never use plastic plugs instead of the
fibre plugs supplied. Screw the eyebolts
into the plugs. Make sure that the bolts
are secure.
Place the convection box unit close to the
fireplace but allow sufficient access into
the fireplace opening so that the cables
can be threaded through the eyebolts and
returned through the back of the
convection box. If a concealed connection
is being used, insert the convection box
into the fireplace feeding the supply pipe
through a suitable gas inlet point.
The convection box has two holes at each
end of the debris deflector. Insert one
end of each cable (one cable each side)
from the back through the lower of the
two holes and return the end through the
upper of the holes (see figure 10). Give
the cables a pull so that they grip against
the debris deflector flanges.
Thread the cables through the eyebolts in
the rear wall. Return the cables through
the holes near the bottom of the
convection box back panel and through

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dream fireslid 9500435Dream fireslid 9500434

Table of Contents