Check For Spillage - Valor Dream Fireslid 9500433 Installer's Manual

Inset live fuel effect gas fire with either
Table of Contents

Advertisement

Valor 600B610_01
7/12/00
Open the isolating valve on the inlet elbow.
8.1.2
Slide the button to the bottom (ignition)
8.1.3
position marked ?. Retain in this position
to ignite the pilot. The burner should
ignite at its lowest setting within 4
seconds of the pilot igniting. Keep at this
position for a further 10 seconds to allow
the pilot flame to stabilise.
figure 23
Spillage check
Release the button. The button should
8.1.4
automatically spring up to the low heat
position. If the flames go out at this stage
or when checking the rest of the setting
positions, try the full lighting sequence
again. If the flames fail after two attempts,
investigate the pilot unit.
Gradually slide the button up to increase
8.1.5
the burner setting. The burner should be
at its maximum setting at the high heat
position shown in figure 22. You should
feel a check to the button movement at
this position.
Slide the control button up past the high
8.1.6
heat position to the off ("O") position at
the top of the slide slot. Both pilot and
main burner should go out.
While cooling the coals may make some
crackling noises. This is quite normal.
3:22 PM
Page 13
INSTALLER GUIDE
8.2
8.2.1
8.2.2
8.2.3
8.2.4
8.2.5
8.2.6
8.2.7
Page 13

Check For Spillage

A spillage check must be made before
leaving the installed appliance with the
customer.
Make this check with the appliance fully
installed with the ceramics and fascia
casting in position.
Close all doors and windows in the room
containing the appliance.
Light the appliance and set the slide
control to the maximum burning position.
Leave the appliance on for five minutes.
Fit a smoke match into a tube, light it and
insert it into the appliance canopy at the
position shown in Fig.23.
The installation is satisfactory if the
smoke is drawn into the appliance. If the
smoke is not drawn into the appliance,
leave the appliance alight at the maximum
setting for a further ten minutes and then
repeat the test. If smoke is still not drawn
into the appliance, inspect the sealing to
the fireplace surround. If smoke is still not
drawn into the appliance, disconnect the
appliance and seek expert advice.
If the above test is satisfactory, open all
internal connecting doors, hatches,
etc., in the room. Keep all doors and
windows that open to the outside of the
building closed. Recheck for spillage as
above. If an extractor fan is installed in
the same room as the appliance or a
connecting room, check that spillage does
not occur with the fan operating and all
doors and other openings between the fan
and the appliance open.
If the smoke is drawn into the appliance,
continue with the installation. If the
test is not satisfactory, disconnect the
appliance and advise the customer of
the cause of failure.