Preliminary Checks; Unpacking; Check Ignition Spark - Valor Dream Fireslid 9500433 Installer's Manual

Inset live fuel effect gas fire with either
Table of Contents

Advertisement

Valor 600B610_01
7/12/00
A twin wall metal flue system
2.10.2
conforming to BS715, the flue
Diameter being a minimum of 125mm
(See figure 2) with a minimum internal
depth of 250mm. Incombustible
mineral wool insulation of not less than
50mm thickness must be applied to the
top surface of the system firebox and
must stand on a non-combustible base
of 25mm thickness.
The appliance must be mounted behind
2.11
a non-combustible hearth with minimum
dimensions as figure 3. (n.b
conglomerate marble hearths are
considered as non-combustible). The
appliance can be fitted to a purpose
made proprietary class "O" 150∞C
surround. The hearth material must be
at least 12mm thick. The periphery of
the hearth (or fender) should be at least
50mm above floor level to discourage
the placing of carpets or rugs over it.
The appliance must not stand on
combustible materials or carpets.
The appliance must not be fitted
directly against a combustible wall.
If the appliance is to be fitted against a
wall with combustible cladding, the
cladding must be removed from the area
covered by the appliance outer
surround. We suggest that the actual
surround is used as a template to mark
the area for combustible cladding
removal.
.
The flue must not be used for any other
2.12
appliance or application.
.
If the fireplace opening is of underfloor
2.13
draught type, it must be sealed to stop
any draughts.
An extractor fan may only be used in the
2.14
same room as this appliance, or in any
3:22 PM
Page 6
INSTALLER GUIDE
2.15
3.1
3.2.
3.2.1
Page 6
area from which ventilation for the
appliance is taken, if it does not affect
the safe performance of the appliance.
Note the spillage test requirements
detailed further on in this manual. If the
fan is likely to affect the appliance, the
appliance must not be installed unless
the fan is permanently disconnected.
Propane gas appliances must not be
installed in a room, which is built entirely
below ground level (see BS 5871 Part 2).

3. PRELIMINARY CHECKS

Unpacking

Carefully remove the contents. Take
special care in handling the ceramic
coals. Take care not to bend or distort the
slide control linkage when handling the
burner and convection box unit.
Check that all the listed parts are present
and in good condition.

Check Ignition Spark

Before attempting to install, it is worth
checking that the electronic ignition
system performs satisfactorily.
Fit the battery to the ignition block located
below the burner tray at the left side (see
figure 4). The positive terminal (+) is to
the right as you insert.
figure 4
Battery fitting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dream fireslid 9500435Dream fireslid 9500434

Table of Contents