Installer Section; Appliance Data; General Installation Requirements - Valor Dream Fireslid 9500433 Installer's Manual

Inset live fuel effect gas fire with either
Table of Contents

Advertisement

Valor 600B610_01
7/12/00

1.APPLIANCE DATA

This product uses fuel effect pieces containing
Refractory Ceramic Fibres (RCF), which
are man-made vitreous silicate fibres. Excessive
exposure to these materials may cause
temporary irritation to eyes, skin and respiratory
tract. Consequently, it makes sense to
take care when handling these articles to ensure
that the release of dust is kept to a
minimum. To ensure that the release of fibres
from these RCF articles is kept to a
minimum, during installation and servicing we
recommend that you use a HEPA
filtered vacuum to remove any dust and soot
accumulated in and around the fire before
and after working on the fire. When replacing
these articles we recommend that the
replaced items are not broken up, but are sealed
within a heavy duty polythene bag,
clearly labelled as RCF waste. This is not
classified as "hazardous waste" and may be
disposed of at a tipping site licensed for the
disposal of industrial waste. Protective
clothing is not required when handling these
articles, but we recommend you follow the
normal hygiene rules of not smoking, eating or
drinking in the work area and always
wash your hands before eating or drinking.
This appliance does not contain any component
manufactured from asbestos or
asbestos related products.
The appliance data label is on a tie below the
burner and is visible when the bottom
front cover is removed.
Gas:
Natural (G20)
Inlet Pressure
20mbar
Input - Max. (Gross)
6.85kW (23,400 Btu/h)
Input - Min. (Gross)
2.7kW (9,410 Btu/h)
Burner Test Pressure (Cold)
17.3±0.75mbar
(7.0±0.3in w.g.)
Gas Connection
8mm pipe
Burner Injector
Bray Cat. 31 Size 440
Pilot & Atmosphere
Sensing Device
SIT Ref. OP9030
Ignition
Electronic (Battery 9V PP3) Electronic (Battery 9V PP3)
Aeration
Non-adjustable
*When converted using kit 591159
3:22 PM
Page 4
INSTALLER GUIDE
2. GENERAL INSTALLATION
2.1
Propane (G31)*
37mbar
6.7kW (22,860 Btu/h)
4.3kW (14,670 Btu/h)
35.1±0.75mbar
(14.1±0.3in w.g.)
8mm pipe
Bray Cat. 18 Size 190
SIT Ref. OPLPG9222
Non-adjustable
Page 4
REQUIREMENTS
The installation must be in accordance with
these instructions.For the user's protection,
in the United Kingdom it is the law that all
gas appliances are installed by competent
persons in accordance with the current
edition of the Gas Safety (Installation and
Use) Regulations. Failure to install the
appliance correctly could lead to
prosecution. The Council for the
Registration of Gas Installers (CORGI)
requires its members to work to recognised
standards.In the United Kingdom the
installation must also be in accordance with:
All the relevant parts of local regulations.The
current edition of the Building Regulations
issued by the Department of the
Environment and the Welsh Office or the
Building Standards (Scotland)
(Consolidation) Regulations issued by the
Scottish Development Department.All
relevant codes of practice.The relevant parts
of the current editions of the following
British Standards:-
BS 715
BS 1251
BS 1289 Part 1
BS 1289 Part 2
BS 4543 Part 2
BS 5440 Part 1
BS 5440 Part 2
BS 5871 Part 2
BS 5872 Part 3
BS 6461 Part 1
BS 6891
In the republic of Ireland the installation
must also conform to the relevant parts of:
The current edition of IS 813
b) All relevant national and local rules in
force.