To Remove The Main Burner Injector; To Replace Burner Plaques; To Remove The Appliance From The Fireplace - Valor Dream Fireslid 9500433 Installer's Manual

Inset live fuel effect gas fire with either
Table of Contents

Advertisement

Valor 600B610_01
7/12/00
figure 34
Burner injector removal
To remove the main burner injector (see
10.10
figure 34)
Remove the burner unit-See section 10.4
10.10.1
Disconnect the main burner pipe from
10.10.2
the injector at the venturi end. If
necessary, loosen the pipe at the flow
rate controller end to swing the pipe
clear of the injector.
Unscrew the injector from the rear
10.10.3
support bracket.
Refit in the reverse order. When refitting
10.10.4
the burner unit, make sure that the
tab at the right side of the battery box is
in front of the "L" shaped bracket which
projects up from the fire case base. See
figure 29.
To replace burner plaques (fig. 35)
10.11
Remove the loose coals, the front base
10.11.1
coal, rear base coal and front burner trim.
Remove the plaque clamping strips by
10.11.2
detaching 8 screws.
Remove the plaques and the
10.11.3
combination gasket between and under
the plaques.
If necessary remove the gauze and the
gasket beneath it.
If necessary fit a new gasket below the
10.11.4
gauze. Clean and replace the gauze. Fit a
new combination gasket below the
plaques. Push the gasket ends inwards
to form a dividing gasket between the
plaques.
Place the new left hand plaque in
10.11.5
position. The left side of the plaque
must touch the inside edge of the
retaining flange at the left side of the
burner well.
Place the new right hand plaque in
10.11.6
3:23 PM
Page 19
INSTALLER GUIDE
10.11.7
10.11.8
10.12
10.12.1
10.12.2
10.12.3
figure 35
Page 19
position. Make sure that the centre
section of the combination plaque is
between the two plaques. If there is any
play between the plaques and the end
retaining flanges, push the plaques
firmly to the left squeezing the centre
section of the combination gasket
between the two plaques. Any gap
should be between the right side of the
plaque and the right side retaining
flange.
Fit the front and rear plaque clamping
strips. Make sure that the plaques are as
far to the left as possible. It is
important that the left side plaque is
accurately positioned so that it has the
correct relationship to the pilot. Fully
tighten the clamping strips.
Refit the coals as described in the
installation instructions.
To remove the appliance from the
fireplace
Remove the "ash pan" casting, bottom
front casting, loose coals, front base
coal and rear base coal.
Slacken the hexagonal adjusters on the
cable retainers and unscrew the
thumbscrews to release the cables.
Refit as described in the relevant
installation sections.
Burner plaque positions

Hide quick links: