terminal, shall be not less than 3m in actual vertical height. When calculated in
accordance with BS 5440: Part 1 Annex B, the minimum equivalent height of the
flue shall be 2.0m of 125mm dia. flue pipe.
- The flue must be clear of any obstruction and its base must be clear of debris.
- The flue must be completely sealed so that combustion products do not come into
contact with combustible materials outside the chimney.
- The flue must serve only one fireplace.
- Proprietary terminals must comply with BS EN 1858, BS EN 1806 or BS 1289 and
older versions of BS 715. Any terminal or termination must be positioned in
accordance with BS 5440 Part 1 to ensure that the products of combustion can be
safely dispersed into the outside atmosphere. Where the appliance is connected
to an unlined brick chimney it is generally unnecessary for the chimney pot to be
replaced or for a terminal to be fitted unless the flue has a diameter smaller than
170mm.

5. PRE-INSTALLATION PREPARATION

5.1 Unpacking.

This appliance is supplied completely assembled except for:-
4 radiants which are in a cardboard pack inside the firebox.
-
The closure plate
-
Literature pack
-
An olive & olive nut for gas line connection
-
Rear baffle for closure plate coverage (where required)
-
Battery (Only supplied with electronic ignition models)
-
Control knob.
-
4 Fixing extension brackets.
-
4 flat head self tapping screws (For securing the upper extension brackets).
Remove all the items carefully to prevent damage. Some items may be contained in
-
the packaging fitments - Examine the packaging carefully before discarding. Check
that all the items are present and undamaged.

5.2 Appliance preparation.

1. Stand the fire upright.
2. Remove the two transit screws from near the top of the back panel wings (See
figure 5).
3. Remove the control knob by pulling clear of the gas tap spindle.
4. Remove the two fascia retaining screws located at the rear of the fascia near the
bottom corners.
5. Gently lift the fascia up and forward to clear the rear top location. Store in a safe
place.
©
GDC Group Ltd. OCT 2016
INSTALLER GUIDE
Page 17

Advertisement

Table of Contents
loading

Table of Contents