CAUTION: Do not abuse the appliance's glass by striking, slamming or similar trauma.
Do not use the appliance with the window removed, glass panel cracked or broken.
Only use glass approved for use with this heater. Do not use substitute materials.
Replacement of the panel should only be carried out by a licensed qualifi ed service
person.
Do not remove the window when the appliance is hot. Not only is it dangerous but it
could cause damage to the gasket.
9.1 Window Removal
•
At the bottom corners of the window, turn the two spring-loaded bolts 90
degrees to release the window from the fi rebox.
•
Pull the bottom of the window away from the fi rebox while lifting it
off the top rail.
•
Carefully lift the window away and put aside in a safe location to
avoid damage.
•
When reinstalling, follow the instructions from the section Window
f i r e - p a r t s . c o m
Refi tting on page 20.
9.2 Ignition Spark Check
The pilot burner and electrode unit are at the left end of the burner.
Push in the lighting knob and turn it counter-clockwise through the "IGN"
position to "PILOT". A spark should fl ash across from the pilot electrode to the
pilot burner shield as shown below.
Spring-loaded bolts
14
Appliance Preparation
2
1
Thermostat Knob
Gas Control Knob