4. MAINTENANCE
Battery replacement
This appliance requires 9V PP3 Ever Ready
Silver Seal (or equivalent) battery.
To replace the battery remove the bottom
front cover casting.
Fit the new battery firmly to the connections
on the generator, the positive battery
terminal (+) being to the right as you insert.
See figure 10.
Regular maintenance
In order to achieve and maintain high levels
of personal safety and performance
efficiency, it is essential that the opening at
the back of the fire and the flue are kept
clear of any form of obstruction. It is
possible that deposits of mortar or soot
could fall and accumulate causing the flue to
be blocked or restricted and so preventing
proper clearance of dangerous exhaust
fumes.
In the United Kingdom it is the law that a
landlord must have any gas appliance, flue
and pipework which is situated in a tenant's
premises checked for safety at least every
twelve months by a competent person (In
the U.K, a CORGI registered installer).
We recommend that all gas appliances and
their flues, wherever situated, are checked
annually.
Servicing
In the United Kingdom servicing can be
carried out either by a Valor Service
engineer or a CORGI registered installer.
If you require your fire to be serviced,
please contact
Valor Service on
0121 386 6203 and quote the following
details;
a) - model name and number.
b) - appliance serial no. (To be found below the
burner and behind the bottom front cover)
If you wish to replace any of the owner
replaceable parts listed below, please
contact Valor Sales on 0121 386 6260 for
your nearest stockist of these parts. When
ordering please quote the part number
shown below.
From the Republic of Ireland call
0044 121 373 8111 for all enquiries.

USERS INSTRUCTIONS

Description
Rear base coal
Front base coal
Bag of 14 loose coals
When fitting replacement parts, follow the
instructions contained in this guide. It is
important that only Valor approved parts
are used for maximum safety.
figure 10

USEFUL TELEPHONE NUMBERS

To help us quickly help you, please try to have the following
a)
b)
c)
d)
e)
General advice about gas and your gas fire:
VALOR ADVICELINE
To report faults or arrange for your fire to be
serviced:
VALOR SERVICE
To order spares or for sales information:
VALOR SALES
CALLERS IN THE REPUBLIC OF IRELAND
Call 0044 121 373 8111
Page 8
Part No
565739
569579
563339
Battery fitting
information available before you contact us:
Your Post Code.
Type of fire.
Model/Name.
Serial Number.
The fault, problem or request.
0345 626341.
0121 386 6203.
0121 386 6260.

Hide quick links: