Check The Fireplace; Fireplace Flue Pull; Preparing Appliance For Installation; Gas Supply Connection - Valor Dream Fireslid 9500433 Installer's Manual

Inset live fuel effect gas fire with either
Table of Contents

Advertisement

Valor 600B610_01
7/12/00
Depress the slider as far as it will go.
3.2.2
This should close the ignition circuit.
Sparks should be seen tracking from the
electrode pin to the thermocouple tip
(see figure 5). If there are no sparks
make the following checks.
a) Check condition of battery and that it
is correctly fitted.
b) Check spark gap between electrode
wire and thermocouple tip (see figure 6).
c) If a & b are satisfactory, check the
ignition circuit and components - see the
servicing section in this manual.
figure 5
Slider control
figure 6
Pilot ignition system

Check The Fireplace

3.3.
The fireplace must comply with all the
requirements of section 2.
The fireplace floor should be reasonably
flat to ensure that the convection box can
be installed without it rocking and so that
a good seal can be made at the bottom
front of the box. The front face of the
3:22 PM
Page 7
INSTALLER GUIDE
3.4.
4.PREPARING APPLIANCE FOR
4.1.
Page 7
fireplace should be reasonably flat over
the area covered by the convection box
top and side flange seals to ensure good
sealing. These faces should be made
good if necessary. If the appliance is to
be fitted against a wall with combustible
cladding, the cladding must be removed
from the area covered by the outer
surround. We suggest that the actual
surround is used as a template to mark
the area for combustible cladding
removal.

Fireplace Flue Pull

After preparing the fireplace, carry out
the flue flow test as detailed in BS5440:
Part 1. Note - A 13 gramme smoke pellet
will generate the required volume of
smoke, anything smaller may give a false
pass result. Observe the smoke. If there
is a definite flow into the opening
continue with the installation. If there is
not a definite flow, preheat the chimney
for ten minutes and recheck. If there is
still no definite flow, the chimney may
need attention. Do not fit the appliance.
Seek expert advice.
INSTALLATION

Gas Supply Connection

8mm Bundy or semi-rigid tubing must be
used to connect the appliance to the gas
supply. Centre the appliance in the
fireplace opening taking care not to
scratch or damage the hearth. If a
concealed gas pipe fixing is to be used,
offer the gas pipe through the
appropriate grommet. A nut and olive are
provided for an 8mm pipe inlet
connection to the elbow at the bottom
front of the appliance. The elbow can be
rotated to allow a connection from
any direction. The elbow includes a valve
for isolating the gas supply.

Hide quick links: