Appliance Preparation - Valor Regency OXYSAFE 2 Installer's Manual

Table of Contents

Advertisement

defective flue. If there is not a definite flow warm the flue
for a few minutes and repeat the smoke pellet test. If there
is still no definite flow the flue may need remedial work –
Do not fit the appliance until there is a definite flow
through the flue.

5.3 Appliance Preparation

5.3.1. Stand the fire upright.
5.3.2 Remove the two transit screws from near the top of
the back panel wings. See figure 4.
5.3.3. Remove the control knob by pulling clear of the gas
tap spindle.
5.3.4. Remove the two case retaining screws located at the
front of the case near the bottom corners.
5.3.5. Lift the case up and forward to clear the rear top
location. Store in a safe place.
5.3.6. Remove the radiant pack.
5.3.7. Remove any protective film from all the bright trims.
5.3.8. Check ignition spark: Before attempting to install, it
is worth checking that the piezo electric spark ignition
system operates satisfactorily.
To initiate the spark, temporarily refit the control knob to
the spindle. Depress the knob and while keeping it
depressed, turn to the 1/IGN position. A spark should track
from the electrode pin to the thermocouple tip. If there is no spark or incorrect tracking,
check the spark gap between the electrode wire and thermocouple tip. See figure 5.
If the spark gap is correct, check the ignition wiring.
5.3.9. If the fire is fitted to a recessed fireplace, an extension flue spigot up to a maximum
total length of 125mm may be used. The extension must be a tight fit over the flue spigot
and be secured by two self tapping screws. Note the minimum clearance required as
shown in figure 2.
INSTALLER'S GUIDE
Page 12
Figure 4. Transit screws
Figure 5.
Pilot spark gap