Error 92 - Sony CBK-HD01 Maintenance Manual

Professional disc camcorder; hd/sd sdi input board; analog composite input board
Table of Contents

Advertisement

3-2-8. Error 92

When synchronization system errors are detected, the following error codes are displayed.
n
System control CPU: IC200 on the SY-355 board
Main
Sub
Time data
code
code
display
92
101
102
3-2-9. Error 95
When interface errors between device ICs are detected, the following error codes are displayed.
n
System control CPU: IC200 on the SY-355 board
Optical drive's system control CPU (DRV): IC600 on the DR-606 board
Main
Sub
Time data
code
code
display
95
101
102
103
104
107
during
recording
109
during
playback
108
during
recording
10A
during
playback
10C
10F
during
recording
110
during
playback
111
PB DSP
113
REC DSP
116
PDW-700/V1 (E)
Maintenance
Drive
Description
logger
logger
O
X
System control CPU detects REF error.
O
X
System control CPU detects frame error in input system.
Maintenance
Drive
Description
logger
logger
O
X
Communication error between system control CPU and PCI bridge
(IC900/SY-355 board) is detected.
O
X
Communication error between system control CPU and FAM (IC600/SY-
355 board) is detected.
O
X
Communication error between system control CPU and composite
decoder (IC100/IV-59 board) is detected.
O
X
Communication error between system control CPU and MPEG IMX
encoder (IC1600/DVP-45 board) is detected.
O
X
Communication error between system control CPU and MPEG HD codec
(TORINO: IC1000,IC1200,IC1400/DVP-45 board) is detected during
recording.
O
X
Communication error between system control CPU and MPEG HD codec
(TORINO: IC1000,IC1200,IC1400/DVP-45 board) is detected during
playback.
O
X
MPEG HD codec (TORINO: IC1000, IC1200, IC1400 / DVP-45 board) has
become abnormal during recording.
O
X
MPEG HD codec (TORINO: IC1000, IC1200, IC1400 / DVP-45 board) has
become abnormal during playback.
O
X
System control CPU detects an error in LVIS (IC400 / DVP-45 board).
O
X
System control CPU detects PROXY VIDEO block in LVIS (IC400 /
DVP-45 board) error during recording.
O
X
System control CPU detects PROXY VIDEO block in LVIS (IC400 /
DVP-45 board) error during playback.
O
X
Communication error between system control CPU and PB DSP (IC801/
DVP-45 board) is detected.
O
X
Communication error between system control CPU and REC DSP (IC800/
DVP-45 board) is detected.
O
X
Communication error between system control CPU and PROXY AUDIO
DSP (IC900/DVP-45 board) is detected.
(Continue)