Sony CBK-HD01 Maintenance Manual page 164

Professional disc camcorder; hd/sd sdi input board; analog composite input board
Table of Contents

Advertisement

CCD ADJUST 1
S07 CCD ADJUST 1
R CCD GAIN
G CCD GAIN
B CCD GAIN
R TEST SAW GAIN :
G TEST SAW GAIN :
B TEST SAW GAIN :
TEST SAW
TEST OUT SELECT :
Item
Setting
R CCD GAIN
-99 to 99
G CCD GAIN
-99 to 99
B CCD GAIN
-99 to 99
R TEST SAW GAIN
-99 to 99
G TEST SAW GAIN
-99 to 99
B TEST SAW GAIN
-99 to 99
TEST SAW
OFF/ON
TEST OUT SELECT
VBS/Y/R/G/B/LCD
CCD ADJUST 2
S08 CCD ADJUST 2
R VSUB
G VSUB
B VSUB
R VSUB OFST (P) : ±0.0V
G VSUB OFST (P) : ±0.0V
B VSUB OFST (P) : ±0.0V
CCD H DRIVER
AD CLOCK PHASE
TEST OUT SELECT :
Item
Setting
R VSUB
9.0 V to 18.0 V (0.1 V step)
G VSUB
9.0 V to 18.0 V (0.1 V step)
B VSUB
9.0 V to 18.0 V (0.1 V step)
R VSUB OFST (P)
-5.0 V to +5.0 V (0.1 V step)
G VSUB OFST (P)
-5.0 V to +5.0 V (0.1 V step)
-5.0 V to +5.0 V (0.1 V step)
B VSUB OFST (P)
CCD H DRIVER
5.2 V/5.4 V/5.6 V/5.8 V/6.0 V/6.2 V
AD CLOCK PHASE
-2/-1/± 0/+1/+2
TEST OUT SELECT
VBS/Y/R/G/B/LCD
*1 : The default value varies depending on the set.
*2 : The setting that enters the Camcorder in the progressive reading
• When the SYSTEM LINE is 1080 and SYSTEM FREQUENCY is 29.9P, 25P or 23.9P at the same time, or when the slow shutter function is set to ON.
• When the SYSTEM LINE is 720 and the SYSTEM FREQUENCY is 59.9P, and at the same time SCAN MODE is 23.9P.
For example, the V. substrate voltage of the R-channel in 1080/29.9P becomes the sum of R VSUB setup value and the R VSUB OFST (P) setup value.
4-74
TOP
:
0
:
0
:
0
0
0
0
:
OFF
VBS
TOP
: 14.0V
: 14.0V
: 14.0V
:
6.0V
±0
:
VBS
*1
*1
*1
Function
Adjusts the sensitivity of the R-channel
Adjusts the sensitivity of the G-channel
Adjusts the sensitivity of the B-channel
Adjusts the GAIN of the R-channel test saw
Adjusts the GAIN of the G-channel test saw
Adjusts the GAIN of the B-channel test saw
Turns ON/OFF the test saw function
Selects the video signal of the TEST OUT connector
Function
Sets the V. substrate voltage of the R-channel
Sets the V. substrate voltage of the G-channel
Sets the V. substrate voltage of the B-channel
Adjusts the offset for the V. substrate voltage of the R-channel during the
*2
progressive reading
Adjusts the offset for the V. substrate voltage of the G-channel during the
*2
progressive reading
Adjusts the offset for the V. substrate voltage of the B-channel during the
progressive reading
*2
Sets the drive voltage of the CCD H DRIVE
Sets the phase frequency of AD
Selects the video signal of the TEST OUT connector
PDW-700/V1 (E)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: