Error 3X; Error 5X; Error 6X - Sony CBK-HD01 Maintenance Manual

Professional disc camcorder; hd/sd sdi input board; analog composite input board
Table of Contents

Advertisement

3-2-4. Error 3X

When errors related to the optical drive sensor system are detected, the following error codes are dis-
played.
Main
Sub
Time data
code
code
display
34
500
509
35
500
ACC Sensor!
37
500
High TEMP!
3C
500
HUMID!

3-2-5. Error 5X

When read data errors are detected, the following error codes are displayed.
Main
Sub
Time data
code
code
display
50
010
(Not displayed) X
(Not displayed) X
011
51
020
DI read err
021
DI read err
52
X0B
Read err

3-2-6. Error 6X

When errors related to startup operation are detected, the following error codes are displayed.
Main
Sub
Time data
code
code
display
60
E00
(Not displayed) X
6F
E00
DRV ADJ err
PDW-700/V1 (E)
Maintenance
Drive
Description
logger
logger
O
O
Loader position sensor (SE-709 board) is detects abnormal code.
O
O
Sensor hole (SE-857,858 board) is detects abnormal code.
X
O
Abnormality of acceleration sensor is detected.
X
O
The temperature sensor of the optical block assembly is abnormal.
X
O
Dew condensation is detected.
Maintenance
Drive
Description
logger
logger
O
BCA area data cannot be read.
O
BCA area data is abnormal.
X
O
PIC area data cannot be read.
X
O
PIC area data is abnormal.
X
O
Address cannot be read from disc in optical block assembly.
Maintenance
Drive
Description
logger
logger
O
Optical block assembly cannot seek to target position during startup.
X
O
Optical block assembly startup adjustment cannot be completed.
3-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cbk-sc02Pdw-700Pdw-f800

Table of Contents