Sub Code
n
Any number of the following is applicable for "X" in the sub codes below, showing an operation status
where the error is detected.
Example) Error 0X (X27)
X27→827: Laser current of optical block assembly is abnormal (zero or excessive) "during
horizontal move of unloading".
Example) Error 5X (X0B)
X0B→80B: Address cannot be read from the disc in optical block assembly "during horizontal
move of unloading".
0:
Operation cannot be identified or no need to be identified.
1:
During loading
2:
During vertical move of loading
3:
Disc is not rotating
4:
Seeking
5:
Reading
6:
Writing
7:
Standby state
8:
During horizontal move of unloading
9:
During vertical move of unloading
A:
During disc removal
B:
During lens cleaning or device checking
C, D: (Not used)
E:
During startup adjustment of optical block assembly
F:
During power-on initialization of optical block assembly SA actuator

3-2-3. Error 20

When errors related to loader assembly are detected, the following error codes are displayed.
Main
Sub
Time data
code
code
display
20
018
111
117
118
211
213
217
218
811
818
911
918
3-4
Maintenance
Drive
Description
logger
logger
O
O
An abnormal current of the loading motor is detected.
O
O
Horizontal move of loading did not end within the predetermined time.
O
O
Displacement of cartridge is detected in the loader during horizontal move of
loading.
O
O
An abnormal current of the loading motor is detected during horizontal move
of loading.
O
O
Vertical move of loading did not end within the predetermined time.
O
O
Cartridge cannot be detected after loading.
O
O
Displacement of cartridge is detected in the loader during vertical move of loading.
O
O
An abnormal current of the loading motor is detected during vertical move of
loading.
O
O
Ejection operation did not end within the predetermined time.
O
O
An abnormal current of the loading motor is detected during the ejection
operation.
O
O
Unchucking operation did not end within the predetermined time.
O
O
An abnormal current of the loading motor is detected during the unchucking
operation.