Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
Zoom operations fault
E
6
1
1
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of the focus
E
6
1
1
1
lens and the abnormalities in initialization of
the zoom lens occurred simultaneously.
Reset position detection error on the stepper
E
6
1
3
0
iris initializing
Handshake correction function does not work
E
6
2
0
0
well. (With PITCH angular velocity sensor
output stopped.)
Handshake correction function does not work
E
6
2
0
1
well. (With YAW angular velocity sensor
output stopped.)
E
6
2
0
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller com-
E
6
2
0
3
munication abnormality among.
I m a g e v i b r a t i o n c o r r e c t i o n d u r i n g
E
6
2
0
4
handshake function does not work.
E
6
2
1
0
Shift lens initializing failure.
E
6
2
1
1
Shift lens overheating (Pitch)
E
6
2
1
2
Shift lens overheating (Yaw)
E
6
2
2
0
Abnormality of thermistor.
E
9
1
0
1
Abnormality when flash is beingcharged.
E
9
1
0
2
Abnormality of LED Video light.
Abnormality of LED Video light Tempera-
E
9
1
0
3
ture detection.
Battery current value goes over the max
E
9
2
0
1
discharge current
Fault of writing or erasing the flash
E
9
4
0
0
memory
E
9
4
0
1
Internal flash memory fault
HDR-PJ50/PJ50E/PJ50V/PJ50VE/XR160/XR160E_L2
Correction
Inspect the lens block zoom reset signal (pin wd, wf of CN4001, pin
rk, if of CN4005 on the LD-279 board or pin rk, if of CN1007 on
the VC-621 board) when zooming is performed when the zoom lever
is operated, and the zoom motor drive circuit (IC5201 on the LD-279
board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Turn the power on to open lens barrier. Disconnect the battery or power
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens
drive block (CN4001 pin rf, to t; or CN4002 pin qj, qk on LD-279
board).
If iris blades work normally, confirm that they are closing completely
and confirm following item.
・ Case of the iris blades do not close normally Replace the lens
block).
・ Case of "E: 61: 30" is appeared and iris blades closed completely.
Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally Check that connection be-
tween CN6901 on CM-114 board and CN1004 on VC-621 board
by FP-1324 flexible board.
・ Case of LCD is displayed normally Replace the lens block.
Inspect PITCH angular velocity sensors (SE7501 on the MS-454
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE7501 on the MS-454 board)
peripheral circuits.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
Inspect the steadyshot circuit (IC5501 on the LD-279 board).
Inspect the image vibration angular velocity sensors (SE7701 on the
LD-279 board) peripheral circuits.
Replacement of lens block. (Note 3) If an error occurs again, replace
the LD-279 board.
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Oc-
curred].
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Oc-
curred].
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
Checking of flash unit or replacement of LED Flash/Video light
(C7210).
Checking of flash unit or replacement of LED Flash/Video light
(C7210).
Checking of flash unit or replacement of LED Flash/Video light
(C7210).
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each out-
put of DC/DC converter (IC4301 on the VC-621 board) on VC-621
board with connected the DC JACK (CN1008).
(The minimum connection to periphery)
Turn power off and turn power on again.
Turn power off and turn power on again.
Self-diagnosis Code
Symptom/State
Block
Detailed
Function
Code
*
E
9
4
0
2
BGM data error
E
9
5
0
0
GPS hardware error
E
9
6
0
0
Map area mount error
E
9
7
0
0
Projector hardware error
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.

1-5. METHOD OF COPING WITH SHIFT LENS ERROR

LD-279 BOARD (SIDE A)
Measurement points on the LD-279 board
1-2
Correction
Check the CPU (IC1301 on the VC-621 board).
PJ50V/PJ50VE:
Check whether the FFC-254 flexible flat cable is broken,and check
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of
the GP-037 board.
PJ50V/PJ50VE:
Inspect or replacement of the HDD.
PJ50/PJ50E/PJ50V/PJ50VE:
Turn power off and turn power on again.
LD-279 BOARD (SIDE B)
IC5501
R5505
Fig. 1
– ENGLISH –

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdr-pj50eHdr-pj50vHdr-pj50veHdr-xr160Hdr-xr160e

Table of Contents