Chint Power CPS SCA20KTL-DO Installation And Operation Manual page 103

Cps sca series grid-tied pv inverter
Table of Contents

Advertisement

Rated Output Frequency
Output Frequency Range
Power Factor
Current THD
AC Disconnection Type
System
Topology
Max. Efficiency
Euro Efficiency
Stand-by / Night
Consumption
Protective Class
Overvoltage Category
Environment
Protection Degree
Cooling
Operating Temperature
Range
Operating Humidity
Operating Altitude
Display and Communication
Display
Communication
Mechanical Data
Dimensions (WxHxD) (mm)
Weight (kg)
Safety
Safety and EMC Standard
3
The Output Frequency Range may differ according to specific grid standard.
3
Variable speed cooling fans
- 25° C to +60° C (derating from +45° C)
4000m (derating from 2000m)
Standard: RS485, Option: Ethernet, Zigbee
LVD: 2006/95/EC EMC: 2004/108/EC, IEC/EN
IEC/EN 62109-2: 2011; IEC/EN61000-6-2:
2005, IEC/EN61000-6-3: 2007
99
70.4A RMS@20ms
50Hz/60Hz
47-53Hz/57-63Hz
>0.99 (± 0.8 adjustable)
<3%
-
Transformerless
98.3%
97.8%
<20W / <2W
I
PV (II), Mains(III)
IP65
0-100%, non-condensing
LCD + LED
600x1000x230
55
62109-1: 2010,

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CPS SCA20KTL-DO and is the answer not in the manual?

Questions and answers

Table of Contents