Toshiba RAV-SM563UT-E Service Manual page 32

Air-conditioner split type
Hide thumbs Also See for RAV-SM563UT-E:
Table of Contents

Advertisement

RAV-SM803UT-E, RAV-SM802BT-E, RAV-SM802CT-E / RAV-SM803AT-E
Outer diameter of refrigerant pipe
Gas side ØA
Liquid side ØB
15.9mm
Height difference (m)
Outdoor unit
at upper side
30
TS
TD
sensor
sensor
Accumulator
(1000cc)
Rotary
compressor
(DA150A1F-20F)
(MPa)
Pd
Standard
3.28
Cooling
Overload
3.59
Low load
1.85
Standard
2.53
Heating
Overload
3.42
Low load
1.99
4 poles are provided to this compressor.
*
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
9.5mm
Outdoor unit
at lower side
30
2-step
muffler
Ø25 × 200L
4-way valve
(STF-0213Z)
Muffler
Ø19 × L160
Pressure
Pipe surface temperature (°C)
(kg/cm²G)
Discharge
Ps
Pd
Ps
(TD)
0.86
33.4
8.8
84
1.00
33.6
10.2
82
0.83
18.9
8.5
42
0.62
25.8
6.3
75
1.07
34.9
10.9
80
0.23
20.3
2.3
89
Indoor unit
Air heat exchanger
TC sensor
Refrigerant pipe
at gas side
Ø15.9
Section shape
of heat insulator
Packed valve
Outer dia. ØA
Outdoor unit
TO sensor
TE
sensor
Heat exchanger
Ø8 ripple, 2 rows,
20 steps
FP1.3 flat fin
4 pass
Indoor heat
Outdoor heat
Suction
exchanger
exchanger
(TS)
(TC)
(TE)
11
10
45
17
16
51
8
6
23
3
42
2
20
54
17
–19
34
–18
– 32 –
Revised : Mar. 2007
TCJ
sensor
Refrigerant pipe
at liquid side
Ø9.5
Min.
5m
Packed valve
Outer dia. ØB
PMV
(Pulse Motor Valve)
(CAM-B30YGTF-1)
Strainer
Distributor
R410A 1.6 kg
Indoor/Outdoor
Compressor
temp. conditions
Indoor
revolutions per
(DB/WB) (°C)
fan
second (rps)
Indoor
*
83
HIGH
27/19
76
HIGH
32/24
35
LOW
18/15.5
95
HIGH
20/–
50
LOW
28/–
120
HIGH
15/–
Max.
30m
Cooling
Heating
Outdoor
35/–
43/–
–5/–
7/6
24/18
–10/(70%)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents