Toshiba RAV-SM563UT-E Service Manual page 158

Air-conditioner split type
Hide thumbs Also See for RAV-SM563UT-E:
Table of Contents

Advertisement

No.
Part name
11
Reactor
1) Perform works of items
2) Remove the connector of the reactor lead
3) Remove fixing screws of the reactor.
Procedure
NOTE)
The same two reactors are installed to this
outdoor unit though each installation place
is different.
One is attached to a partition board, and the
other is attached to an electric parts box.
wire connected to the inverter assembly.
<Cautions for assembling>
The temperature of the reactor becomes
high during operation of the outdoor unit.
Using a cord holder, fix various sensor lead
wires or fan motor lead wires in the sur-
roundings of the reactor to be fixed to the
electric parts box as shown below so that
they do not come to contact with the reac-
tor.
Cord holder
Fan motor lead wire
Various sensor
lead wires

to
.
Reactor
– 158 –
Remarks
Partition board
Reactor
Electric parts box