Toshiba RAV-SM563UT-E Service Manual page 108

Air-conditioner split type
Hide thumbs Also See for RAV-SM563UT-E:
Table of Contents

Advertisement

<In case of wireless remote controller>
Procedure
Turn on power of the air conditioner.
1
The operation is not accepted for 5 minutes when power has been turned on at first time after installation,
and 1 minute when power has been turned on at the next time and after. After the specified time has
passed, perform a test operation.
2
Push [Start/Stop] button and change the operation mode to [COOL] or [HEAT] with [Mode] button.
Then change the fan speed to [High] using [Fan] button.
3
Set temperature to [18°C] using [Temperature set]
button.
4
After checking the receiving sound "Pi", immediately
push [Temperature set] button to set to [19°C]
5
After checking the receiving sound "Pi", immediately
push [Temperature set] button to set to [18°C].
Then repeat the procedure
6
After approx. 10 seconds, all the display lamps on the sensor part of wireless remote controller,
[Operation] (Green), [Timer] (Green), and [Ready] (Yellow) flash and the air conditioner starts operation.
If the lamps do not flash, repeat the procedure
7
After the test operation, push [Start/Stop] button to stop the operation.
<Outline of test operation from the wireless remote controller>
Test cooling operation:
Start → 18°C → 19°C → 18°C → 19°C → 18°C → 19°C → 18°C → (Test operation) → Stop
Test heating operation:
Start → 30°C → 29°C → 30°C → 29°C → 30°C → 29°C → 30°C → (Test operation) → Stop
Be sure to set the
air speed to [High]
Test cooling operation
4
5
4
2
Description
Set temperature to [30°C] using [Temperature set]
button.
After checking the receiving sound "Pi", immediately
push [Temperature set] button to set to [29°C].
After checking the receiving sound "Pi", immediately
push [Temperature set] button to set to [30°C].
5
.
2
and after.
– 108 –
Test heating operation
3, 4, 5, 6
2, 7

Hide quick links: