Toshiba RAV-SM563UT-E Service Manual page 141

Air-conditioner split type
Hide thumbs Also See for RAV-SM563UT-E:
Table of Contents

Advertisement

RAV-SM1103AT-E, RAV-SM1403AT-E / RAV-SP562AT-E, RAV-SP802AT-E
No.
Part name

Common
procedure
1. Detachment
1) Stop operation of the air conditioner, and
2) Remove the front panel.
3) Disconnect the connecting cables and
4) Remove the upper cabinet.
2. Attachment
1) Attach the waterproof cover.
2) Attach the upper cabinet.
3) Connect the connecting cable and power
4) Attach the front cabinet.
Procedure
CAUTION
Never forget to put on the gloves at
working time, otherwise an injury will be
caused by the parts, etc.
also turn off switch of the breaker.
(ST1T Ø4 × 10L, 3 pcs.)
• After taking off screws, remove the front
panel by pulling it downward.
power cord from the terminals and cord
clamp.
(ST1T Ø4 × 10L, 6 pcs.)
CAUTION
Be sure to attach a waterproof cover.
If it is not attached, there is a possibility
that water enters inside of the outdoor unit.
(ST1T Ø4 × 10L, 6 pcs.)
cord at the terminal and fix them with cord
clamp.
CAUTION
Using bundling band sold at a market, be
sure to fix the power cables and indoor/
outdoor connecting cables along the inter-
unit cable so that they do not come to
contact with the compressor, valves and
cables at gas side, and the discharge pipe.
(ST1T Ø4 × 10L, 3 pcs.)
Front
cabinet
– 141 –
Revised : Mar. 2007
Remarks
Upper plate
of cabinet
Water-proof
cove