Hide thumbs Also See for RAV-SM562CT-E:

Advertisement

AIR CONDITIONER
CLIMATISEUR
(TYPE SPLIT)
KLIMAGERÄT
(SPLIT-TYP)
CONDIZIONATORE D'ARIA
AIRE ACONDICIONADO
AR CONDICIONADO
AIRCONDITIONER
ÊËÉÌÁÔÉÓÔÉÊÏ
(ÔÕÐÏÓ SPLIT)
<Under Ceiling Type> / <Type sous le plafond>
<Zwischendeckentyp> / <Tipo sotto il soffitto>
<Modelo de techo> / <Tipo Sob o Tecto>
<Type voor montage boven verlaagd plafond> / <Ôýðïò êÜôù áðü ôçí ïñïöÞ>
Heat Pump Model/Modèle à thermopompe
Geräte mit Heizung/Modello con pompa di riscaldamento
Modelo con bomba de calor/Modelo de bomba térmica
Model met warmtepomp/ÌïíôÝëï ìå Áíôëßá Èåñìüôçôáò
Indoor Unit/Unité intérieure
Raumeinheit/Unità interna
Unidad interior/Unidade interior
Binnenunit/ÅóùôåñéêÞ mïíÜäá
RAV-SM562CT-E
RAV-SM802CT-E
RAV-SM1102CT-E
RAV-SM1402CT-E
Please read this Installation Manual carefully before installing the Air Conditioner.
• This Manual describes the installation method of the indoor unit.
• For installation of the outdoor unit, follow the Installation Manual attached to the outdoor unit.
Veuillez lire attentivement ce Manuel d'installation avant d'installer le climatiseur.
• Ce manuel décrit la procédure d'installation de l'unité intérieure.
• Pour installer l'unité extérieure, reportez-vous au Manuel d'installation fourni avec l'unité extérieure.
Bitte lesen Sie dieses Handbuch sorgfältig, bevor Sie mit der Installation des Klimagerätes beginnen.
• In diesem Handbuch wird die Installation der Raumeinheit beschrieben.
• Um die Außeneinheit zu installieren, folgen Sie den Anweisungen in dem Handbuch, das der Außeneinheit
beiliegt.
Prima di installare il condizionatore d'aria, leggere con attenzione questo manuale d'installazione.
• Questo manuale descrive il metodo d'installazione dell'unità interna.
• Per l'installazione dell'unità esterna, fare riferimento al manuale d'installazione fornito insieme all'unità esterna.
Lea atentamente este Manual de instalación antes de proceder a la instalación del aparato de aire
acondicionado.
• Este manual describe el método de instalación de la unidad interior.
• Para la instalación de la unidad exterior, consulte el Manual de instalación que acompaña a la unidad exterior.
Leia atentamente o presente Manual de Instalação antes de instalar o Ar Condicionado.
• O presente manual descreve o método de instalar a unidade interior.
• Para a instalação de uma unidade exterior, siga o Manual de Instalação que acompanha a unidade exterior.
Lees deze installatiehandleiding zorgvuldig door voordat u de airconditioner gaat installeren.
• Deze installatiemethode beschrijft de installatiemethode van de binnenunit.
• Zie voor de installatie van de buitenunit, de installatiehandleiding bij de buitenunit.
Ðáñáêáëþ äéáâÜóôå ðñïóå÷ôéêÜ ôï Åã÷åéñßäéï ÅãêáôÜóôáóçò ðñéí áðü ôçí åãêáôÜóôáóç ôïõ Êëéìáôéóôéêïý.
• Ôï ðáñüí Åã÷åéñßäéï ðåñéãñÜöåé ôç ìÝèïäï åãêáôÜóôáóçò ôçò åóùôåñéêÞò ìïíÜäáò.
• Ãéá ôçí åãêáôÜóôáóç ôçò åîùôåñéêÞò ìïíÜäáò, áêïëïõèÞóôå ôï Åã÷åéñßäéï ÅãêáôÜóôáóçò ðïõ óõíïäåýåé ôçí
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
(SPLIT TYPE)
(TIPO SPLIT)
(TIPO SPLIT)
(TIPO SPLIT)
(GESPLITST TYPE)
Outdoor Unit/Unité extérieure
Außengerät/Unità esterna
Unidad exterior/Unidade exterior
Buitenunit/ÅîùôåñéêÞ mïíÜäá
RAV-SM562AT-E
RAV-SM802AT-E
RAV-SM1102AT-E
RAV-SM1402AT-E
www.heronhill.co.uk

INSTALLATION MANUAL

MANUEL D’INSTALLATION
INSTALLATIONS-HANDBUCH
MANUALE D’INSTALLAZIONE
MANUAL DE INSTALACIÓN
MANUAL DE INSTALAÇÃO
INSTALLATIEHANDLEIDING
ÅÃ×ÅÉÑÉÄÉÏ ÅÃÊÁÔÁÓÔÁÓÇÓ
SP562AT-E
SP802AT-E
SP1102AT-E
SP1402AT-E
Fax: 01823 665807

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-SM562CT-E

  • Page 1: Installation Manual

    Heronhill - for all your Toshiba requirements INSTALLATION MANUAL MANUEL D’INSTALLATION INSTALLATIONS-HANDBUCH MANUALE D’INSTALLAZIONE MANUAL DE INSTALACIÓN MANUAL DE INSTALAÇÃO AIR CONDITIONER (SPLIT TYPE) INSTALLATIEHANDLEIDING CLIMATISEUR ÅÃ×ÅÉÑÉÄÉÏ ÅÃÊÁÔÁÓÔÁÓÇÓ (TYPE SPLIT) KLIMAGERÄT (SPLIT-TYP) CONDIZIONATORE D'ARIA (TIPO SPLIT) AIRE ACONDICIONADO (TIPO SPLIT)
  • Page 2 Heronhill - for all your Toshiba requirements ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refriger- ant R22 in order to prevent destruction of the ozone layer.
  • Page 3 Heronhill - for all your Toshiba requirements CONTENTS Accessory parts and Parts to be procured locally ..... 1 TEST RUN ................16 PRECAUTIONS FOR SAFETY ..........2 TROUBLESHOOTING ............18 SELECTION OF INSTALLATION PLACE ......4 APPLICABLE CONTROLS ..........19 DRAIN PIPING WORK ............
  • Page 4: Accessory Parts And Parts To Be Procured Locally

    Heronhill - for all your Toshiba requirements Accessory parts and Parts to be procured locally r Accessory parts Part name Q’ty Shape Usage Part name Q’ty Shape Usage Owner’s Man — — Drain hose For connecting drain pipe Installation Manual This manual —...
  • Page 5: Precautions For Safety

    Heronhill - for all your Toshiba requirements PRECAUTIONS FOR SAFETY • Ensure that all Local, National and International regulations are satisfied. • Read this “PRECAUTIONS FOR SAFETY” carefully before Installation. • The precautions described below include the important items regarding safety. Observe them without fail.
  • Page 6 Heronhill - for all your Toshiba requirements PRECAUTIONS FOR SAFETY • After unpacking the unit, examine it carefully if there are possible damage. • Do not install in a place that might increase the vibration of the unit. • To avoid personal injury (with sharp edges), be careful when handling parts.
  • Page 7 Heronhill - for all your Toshiba requirements SELECTION OF INSTALLATION PLACE WARNING • Install the air conditioner at enough strong place to withstand the weight of the unit. If the strength is not enough, the unit may fall down resulting in injury.
  • Page 8 Heronhill - for all your Toshiba requirements SELECTION OF INSTALLATION PLACE Height of ceiling Before installation Set the installable height of the ceiling within 4m, 1. Removal of suction grille otherwise the air distribution will become poor. Slide the suction grille fixing knobs (two positions) If height of ceiling exceeds 3.5m, hot air becomes...
  • Page 9: External View

    Heronhill - for all your Toshiba requirements External view REQUIREMENT Strictly comply with the following rules to prevent damage of the indoor units and human injury. • Do not put a heavy article on the indoor unit. (Even units are packaged) •...
  • Page 10 Heronhill - for all your Toshiba requirements SELECTION OF INSTALLATION PLACE Installation of hanging bolts Pipe knockout hole Use M10 hanging bolts (4 pcs, to be local procure). • In case of taking pipe from the rear side Matching to the existing structure, set pitch according * Cut off the groove section with a plastic cutter, etc.
  • Page 11 Heronhill - for all your Toshiba requirements 2) Hang the unit to the hanging bolt as shown the Installation of indoor unit figure below. • Preparation before holding down main unit * Confirm the presence of the ceiling material beforehand because the fixing method of hanging metal when the ceiling material is set differs from that when the ceiling material is not set.
  • Page 12: Drain Piping Work

    Heronhill - for all your Toshiba requirements DRAIN PIPING WORK Piping/Heat insulating material CAUTION Require the following materials for piping and heat • Following the Installation Manual, insulating at site. perform the drain piping work so that water is properly drained, and apply a...
  • Page 13 Heronhill - for all your Toshiba requirements Connection of drain hose Thermal insulating process • Insert the attached drain hose into the drain pipe • Using the attached drain hose thermal insulator, lap connecting port on the drain pan up to the end.
  • Page 14: Refrigerant Piping And Evacuating

    Heronhill - for all your Toshiba requirements REFRIGERANT PIPING AND EVACUATING • Flaring diam. meter size : A (Unit : mm) Refrigerant Piping • The connecting sections of the refrigerant pipes are - 0.4 Outer diam. of copper pipe provided at the positions in the figure below.
  • Page 15 Heronhill - for all your Toshiba requirements Piping with outdoor unit Open the valve fully • Shape of valve differs according to the outdoor unit. Open the valve of the outdoor unit fully. A 4mm- hexagonal wrench is required for opening the valve.
  • Page 16 Heronhill - for all your Toshiba requirements ELECTRICAL WORK WARNING 1. Using the specified cables, ensure to connect the wires, and fix wires securely so that the external tension to the cables do not affect the connecting part of the terminals.
  • Page 17 Heronhill - for all your Toshiba requirements Cable connection REQUIREMENT • Be sure to connect the cables matching the terminal numbers. Incorrect connection causes a trouble. • Be sure to pass the cables through the bushing of cabling connection port of the indoor unit.
  • Page 18 Heronhill - for all your Toshiba requirements ELECTRICAL WORK Cabling Remote Controller Cabling 1. Remove a screw and then remove cover of the • Strip off approx. 9mm the cable to be connected. electric parts box. • Non polarity, 2 core cable is used for cabling of the 2.
  • Page 19: Test Run

    Heronhill - for all your Toshiba requirements TEST RUN Before test run • Before turning on the power supply, carry out the following procedure. 1) Using 500V-megger, check 1MΩ or more exists between the terminal block 1 to 3 and the earth.
  • Page 20 Heronhill - for all your Toshiba requirements TEST RUN In case of wireless remote controller Procedure Description Turn on power of the air conditioner. The operation is not accepted for 5 minutes when power has been turned on at first time after installation, and 1 minute when power has been turned on at the next time and after.
  • Page 21: Troubleshooting

    Heronhill - for all your Toshiba requirements TROUBLESHOOTING Confirmation and check When a trouble occurred in the air conditioner, the CODE No. check code and the indoor unit No. appear on the UNIT No. display part of the remote controller.
  • Page 22 Heronhill - for all your Toshiba requirements APPLICABLE CONTROLS NOTIFICATION When using the equipment at the first time, it will take a lot of time that the remote controller accepts an operation after power was on. However, it is not a trouble.
  • Page 23 Heronhill - for all your Toshiba requirements In case of installation to high ceiling When the height of the ceiling to be installed exceeds 3.5m, adjustment of air volume is necessary. Set up the high ceiling. • Set according to the basic operation procedure (Exchange by wired remote controller) →...
  • Page 24 Heronhill - for all your Toshiba requirements APPLICABLE CONTROLS Change of lighting time of filter sign To secure better effect of heating According to the installation condition, the lighting time When it is difficult to obtain satisfactory heating due to...
  • Page 25: Group Control

    Heronhill - for all your Toshiba requirements Group control Simultaneous twin system <Twin system> If combining with an outdoor unit, ON/OFF operation of two indoor units is simultaneously available for the twin system. Outdoor unit Indoor unit Indoor unit • For wiring procedure and wiring method, follow to the Remote controller “Electric work”...
  • Page 26 Heronhill - for all your Toshiba requirements APPLICABLE CONTROLS  Procedure example Manual address setup procedure While the operation stops, change the setup. (Be sure to stop the operation of the unit.) CODE No. DATA SETTING TEST UNIT No. R.C.
  • Page 27 Heronhill - for all your Toshiba requirements Procedure Description If there is other indoor unit to be changed, repeat Indoor unit No. before setup change is displayed. procedure to change the setup. UNIT CODE No. When the above setup has finished, push...
  • Page 28 Heronhill - for all your Toshiba requirements INSTALLATION/SERVICING TOOLS Tools Tools Applicable to R22 model Tools Applicable to R22 model ¡ Gauge manifold Flare tool (clutch type) Charge hose Gauge for projection — —— adjustment ¡ Vacuum pump ¡ Electronic balance for...
  • Page 29 Heronhill - for all your Toshiba requirements ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Cleaning of air filter Soak up dust with a cleaner or clean with •...
  • Page 30 Heronhill - for all your Toshiba requirements This product is compliant with Directive 2002/95/EC, and cannot be disposed as unsorted municipal waste. Ce produit est conforme à la Directive 2002/95/CE et il ne peut pas être jeté avec les ordures ménagères non triées.