Table 7–7
ASC
ASCQ
0C
02
0C
03
11
00
11
01
11
02
11
03
11
04
11
0B
11
0C
47
00/01
48
00

7.19.2 Disk Channel Errors

Disk channel errors are similar to disk-detected errors, except they are detected by the X24 Subsystem,
instead of the disk drive. Some disk channel errors are displayed as text strings, others are displayed as
hexadecimal codes.
Table 7–8
lists the error code descriptions. Most disk channel errors are informational because the X24
Subsystem issues retries to correct any problem. Errors that cannot be corrected with retries will result in
another critical event describing the affected array (if any).
Table 7–8
Error Code
Abort LkDn
CRC Error
Dev Busy
Dn/Ov Run
IOTimeout
Link Down
LIP
No Respon
Port Fail
PrtcolError
?Common ASC and ASCQ descriptions
Descriptions
Write error—auto-reallocation failed
Write error—recommend reassignment
Unrecovered read error
Read retries exhausted
Error too long to correct
Multiple read errors
Unrecovered read error—auto-reallocation failed
Unrecovered read error—recommend reassignment
Unrecovered read error—recommend rewrite the data
FC CRC error
Initiator-detected error message received
Disk channel error codes
Description
I/O request was aborted because of third-party loop initialization procedure (LIP).
CRC error on data was received from a target.
Target reported busy status.
Data overrun or underrun has been detected.
X24 Subsystem aborted an I/O request to this target because it timed out.
Link down while communication in progress.
I/O request was aborted because of a channel reset.
No response from target.
Disk channel hardware failure. This may be the result of bad cabling.
X24 Subsystem detected an unrecoverable protocol error on the part of the target.
X24 Troubleshooting