Loop Resiliency Circuit Input/Output Module (Fc-Al) - Impediment RS-1600-X24 User Manual

Table of Contents

Advertisement

RS-1600-X24 User Guide
Table 1–1
Switch
Number
9 & 10
Caution
All mandatory settings must be observed in order for the RS-1600-X24 system to function correctly.
Note
To set Host 1Gb use the Ethernet connected configurator.

1.3.3 Loop Resiliency Circuit Input/Output Module (FC-AL)

The RS-1600-X24 storage Subsystem includes an enclosure with rear facing bays which house two Loop
Resiliency Circuit (LRC) I/O modules with integrated Xyratex X24 RAID controller, known as Storage
Managers (SM) modules. (see
The FC-AL Backplane incorporates two independent loops formed by Port Bypass Circuits within the LRC
I/O modules.
The plug-in SM modules have been designed for integration into a RS-1600-X24 storage Subsystem,
utilizing FCAL interfacing with the host computer system.
Processors housed on the LRC modules provide enclosure management and interface to devices on the
Backplane, PSU, LRC and Ops Panel, to monitor internal functions. These processors operate in a
master slave configuration to allow failover.
The module incorporates the following LED indicators, shown in
• Host Port 0 Signal Good (Green)
• Host Port 1 Signal Good (Green)
• Expansion Port 0 Rx Good (Green)
6
Ops Panel Switch Functions (Default settings for RS-1600-X24 LRC usage at 2Gb/s)
Function
1
Loop Select,
Dual (2x8)
2
Not Used
3
Not Used
4
Not Used
5 & 6
Not Used
7 & 8
Drive Loop Speed
Select
Drive Addressing
Mode Selection
11
SOFT SELECT
12
Not Used
Recommended
Setting
Off
Note: on RS-1600-FC2 enclosures this must be set On.
Sw7
Sw8
On
Off
Off
Off
Sw9
Sw10
On
Off
On
Figure
1–3)
Definition
LRC operates on two loops of 8 drives
Mandatory
Force 2Gb/s
Force 1Gb/s
Mode 2, 2x8 mode. Mandatory
Select Functions using the hardware
switches
Figure
1–7: