Operation

2.1 Before You Begin

Before powering up your RS-1600-X24 enclosure please ensure that all the modules are firmly seated in
their correct bays.

2.2 Power On

Do not operate the Subsystem until the ambient temperature is within the specified operating range. If
the drives have been recently installed ensure they have had time to acclimatize before operating them.
Note
Please refer to Section
Follow the procedure below to power up the enclosure.
1
Apply AC Mains power to the enclosure. Turn the Power Supply/Cooling modules to ON.
2
On the Ops Panel, the Audible Alarm beeps once, all LEDs flash for 7 seconds then the Alarm double
beeps.
3
All LEDs on the Ops Panel should be lit (Green) when the enclosure power is activated (and the disk drive
motors should start).
Note
All LEDs on the Ops Panel should be lit Green at power up to indicate that the system is functioning
correctly. If any show Amber then a problem exists and the procedure in
page 33
should be followed.
Important
If mains power is lost for any reason, on restoration of power the enclosure will re-start
automatically.
2.3
for details of the Ops Panel LEDs and related fault conditions.
Operation
Chapter 4 , "System Status", on
15