If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before
CAUTION
removing any components.
NOTE
Your components may look slightly different than ones shown.
1.
Turn fireplace off.
2.
Shut off gas supply at manual shut-off valve.
3.
Disconnect gas line flex tube from the manual shut-off valve.
4.
Disconnect any wall switch, remote control or thermostat wires
from
top
&
bottom
unplug all components from electrical outlet, disconnect all
wiring
harnesses
5.
Remove upper hood, upper louver.
6.
Remove glass assembly.
7.
Remove logs, pilot shield and ember log refractory.
8.
Remove pilot shield.
9.
Remove optional light kit light cylinders, amber light filters,
and halogen bulbs if installed.
10. Remove screws securing front left and back right log grate
legs. Remove from firebox by lifting front of burner assembly
up out of flange while pushing pilot assembly back slightly.
11. Remove screws securing front burner assembly. Remove front
burner assembly.
12. Remove adjustable venturi mounting spacers.
13. Remove screws securing optional light kit light stands if
installed.
Carefully
push
14. Remove (8) screws securing control board. Lift board up and
out of firebox.
BURNER / LOG GRATE ASSEMBLY
FRONT BURNER ASSEMBLY
PILOT SHIELD
Figure 22a

CONTROL BOARD REMOVAL

terminals
on
gas
valve
attached
to
gas
stands
off
control
or
valve.
board.
Figure 22b
22
REMOVE (2) SCREWS