kozy heat MINNETONKA 55345-MV Installation Manual page 65

Direct vent gas fireplace
Table of Contents

Advertisement

LOW BATTERY DETECTION
REMOTE CONTROL: Remote contr ol batter y lifespan depends on var ious factor s
including battery quality, number of ignitions, changes to room thermostat set point, etc.
When remote control batteries are low, a Battery Icon will appear on the LCD
display before all battery power is lost. When batteries are replaced this icon will
disappear.
BACKUP BATTERY PACK (used when electrical power is interrupted): Backup
batteries lifespan depends on various factors including battery quality, number of
ignitions, changes to room thermostat set point, etc. When backup batteries are low, a
double-beep will be emitted from the IFC control module when it receives an ON/OFF
command from the remote control. This is an alert for a low battery condition of the
backup batteries and after this double-beep warning, no commands will be accepted until
batteries are replaced. When batteries are replaced a beep will be emitted from IFC control
module as soon as powered.
CONTINUOUS PILOT / INTERMITTENT PILOT (CPI/IPI)
This system has the option of a continuous (standing) pilot feature. This allows you to
change from a spark-to-pilot system to a standing pilot system during cold weather
conditions. By having the pilot on continuously, the firebox will remain warm and a draft
is established in the vent, allowing the main burner to turn on with less air-flow
disruption.
With system in OFF position, press Mode Key to index to CPI mode icon. Pressing the
UP Arrow Key will activate the Continuous Pilot Ignition Mode (CPI). Pressing the Down
Arrow Key will return to IPI. A single beep will confirm the reception of the command.
A snowflake icon will be visible during setup of either IPI or CPI modes.
In IPI mode the snowflake is not visible on LCD screen.
In CPI mode the snowflake will remain visible on LCD screen.
RESETTING SYSTEM FOR MANUAL OPERATION
1.
Put ON/OFF switch in OFF position.
2.
Press red SW1 button on IFC control module until the IFC control module emits three
(3) beeps and an amber LED is illuminated, indicating the IFC control module is
ready to synchronize with remote control. Within ten (10) seconds press the red SW1
button on IFC control module again. The pilot will automatically light.
3.
Turn main burner on by pressing ON/OFF switch to ON position, turn off by pressing
ON/OFF switch to OFF position. Pilot will remain lit even if burner is turned off.
When operating fireplace in this capacity, the only function available is burner operation on HI.
AUTOMATIC SAFETY RESTART
This system will execute an automatic turn OFF command within (24) hours of a continued pilot flame ignition. This allows the system to
verify correct safety functions. After turn OFF sequence is completed, the IFC control module will re-execute the latest command.
SYSTEM OPERATION
8
Figure 8a
Figure 8b
LEDs
SW1 Button
Figure 8c
IFC Control Module