TOP STAND-OFF BRACKETS MUST BE ASSEMBLED AND ATTACHED TO FIREPLACE. DO NOT REMOVE.
WARNING
STAND-OFF BRACKETS ARE NOT LOAD BEARING.
NON-COMBUSTIBLE ZONE:
Rigid pipe: 1-1/2" (38mm) above elbow for entire width and depth (behind header) of fireplace.
#800-1 series flexible venting: 1" (25mm) above elbow for entir e width and depth (behind header ) of fir eplace.
14"(356mm)
12"(305mm)
10" (254mm)
19"
483mm
17"
432mm
15"
381mm
10"
254mm
Figure 11a
TO PREVENT GLASS FRAME ASSEMBLY FROM FALLING FROM FIREPLACE AND BECOMING DAMAGED, FOLLOW THESE
CAUTION
INSTRUCTIONS EXACTLY WHEN REMOVING AND INSTALLING GLASS FRAME ASSEMBLY.
REMOVE GLASS FRAME ASSEMBLY
1.
Locate spring-loaded handles securing glass frame assembly at top & bottom of firebox.
2.
Pull bottom handles out and down to release glass frame assembly bottom.
3.
Pull top handles out and up to release glass frame assembly top.
4.
Remove glass frame assembly from fireplace.
INSTALL GLASS FRAME ASSEMBLY
1.
Place glass frame assembly onto fireplace front.
2.
Pull top handles out and down to secure glass frame assembly top.
3.
Pull bottom handles out and up to secure glass frame assembly bottom.
Pull latches out and up to release glass frame
assembly top.
Pull latches out and down to attach glass frame
assembly top.
Pull latches out and down to release glass frame
assembly bottom.
Pull latches out and up to attach glass frame
assembly bottom.
Figure 11b

MANTEL REQUIREMENTS

3
"
4
19mm

GLASS FRAME ASSEMBLY

NON-COMBUSTIBLE MATERIAL ONLY
NON-COMBUSTIBLE ZONE:
NO MATERIALS ALLOWED ON TOP OF FIREPLACE
WITHIN SHADED AREA FOR ENTIRE WIDTH & DEPTH
OF FIREPLACE. THIS AIR SPACE MUST REMAIN OPEN.
HORIZONTAL VENT HEAT SHIELD