TYPICAL INSTALLATION OPTIONS

Kozy Heat wall thimble pass-thru (#800-WPT or #800WPT2) must be used on all horizontal vent runs. Follow instructions on
page 15 of this manual.
IMPORTANT
The horizontal heat shield included with this fireplace must be installed when using a 45-degree elbow directly off top of unit to
horizontally position vent system. EXCEPTION: Corner installations.
NOTE
HORIZONTAL VENT HEAT SHIELD NOT SHOWN FOR CLARITY PURPOSES ONLY.
*
Illustration at right requires a min. 5" (127mm) exterior wall
depth when using minimum horizontal venting. Anything less
than 5" (127mm) exterior wall depth requires adding that depth
to 21-7/8" (556mm) dimension to accommodate minimum venting.
TYPICAL HORIZONTAL INSTALLATION
5" (127mm) exterior wall depth shown*
1"
Figure 10a
TYPICAL CORNER INSTALLATION
Figure 10b
TYPICAL VERTICAL INSTALLATION
Figure 10c
10
1"
*