PILOT AND BURNER EXTINGUISH WHILE IN OPERATION

No LP in tank. Check and refill if necessary.

Glass frame assembly not installed correctly. Refer to corresponding instructions in this manual.

Improper vent cap installation. Adjust if necessary.

Vent cap blockage. Remove debris if necessary.

Improper pitch on horizontal vent. 1/4" (6mm) rise per foot is required on horizontal venting.

Inner vent pipe leaking exhaust gases back into firebox. Check for leaks and repair if necessary.

Excessive draft.
GLASS SOOTING

Improper log placement. Refer to corresponding pages in this installation manual.

Improper venturi setting. Venturi may need to be opened slightly to allow more air into the gas mix.

Improper pitch on horizontal venting. 1/4" (6mm) rise per foot required on horizontal venting.
FLAME BURNS BLUE AND LIFTS OFF BURNER

Improper venturi setting. Venturi may need to be closed slightly.

Improper vent cap installation. Check for proper vent cap installation.

Blockage or vent system leaks.
NO REACTION TO COMMAND

Receiver or transmitter batteries low. Replace batteries.

No communication between remote control and receiver. Reprogram transmitter to receiver. Follow INITIALIZING THE SYSTEM
FOR THE FIRST TIME as outlined in this manual.