Orban OPTIMOD-FM 5500 Operation Manual page 50

Digital audio processor
Hide thumbs Also See for OPTIMOD-FM 5500:
Table of Contents

Advertisement

2-2
INSTALLATION
TYPE 18/3 SVT COR, TYP
(3 x .82 mm
2
)
PLUG FOR
115 VAC
(USA)
TYPE H05VV - F - 0.75
PLUG FOR
230 VAC
(EUROPEAN)
2. Install the appropriate power cord.
AC power passes through an IEC-standard mains connector and an RF fil-
ter designed to meet the standards of all international safety authorities.
The power cord is terminated in a "U-ground" plug (USA standard), or
CEE7 / 7 plug (Continental Europe), as appropriate to your 5500's Model
Number. The green/yellow wire is connected directly to the 5500 chassis.
If you need to change the plug to meet your country's standard and you
are qualified to do so, see Figure 2-1. Otherwise, purchase a new mains
cord with the correct line plug attached.
3. Mount the 5500 in a rack.
The 5500 requires one standard rack unit (1 ¾ inches / 6.4 cm).
There should be a good ground connection between the rack and the 5500 chas-
sis — check this with an ohmmeter to verify that the resistance is less than 0.5.
Mounting the unit over large heat-producing devices (such as a vacuum-tube
power amplifier) may shorten component life and is not recommended. Ambient
temperature should not exceed 45C (113F) when equipment is powered.
Equipment life will be extended if the unit is mounted away from sources of vi-
bration, such as large blowers and is operated as cool as possible.
4. Connect inputs and outputs.
See the hookup and grounding information on the following pages.
WIRE COLOR
CONDUCTOR
NORMAL
L
LINE
BROWN
NEUTRAL
N
BLUE
E
EARTH GND
GREEN-YELLOW
CONDUCTOR
WIRE COLOR
L
LINE
N
NEUTRAL
E
EARTH GND
GREEN-YELLOW
Figure 2-1: AC Line Cord Wire Standard
ORBAN MODEL 5500
ALT
BLACK
WHITE
GREEN
BROWN
BLUE