6. HOW TO COMMUNICATE WITH ID TAGS
6 - 24
(2) Program example
Set parameters
M1000
Set
parameters
<CH1 communication specification
U0\
MOV
K0
G1
<CH1 processing specification
U0\
MOV
K0
G2
<CH1 auto command wait time setting >
U0\
MOV
K0
G10
<CH1 processing result monitor switch setting>
U0\
MOV
K0
G11
<CH2 communication specification
U0\
MOV
K0
G4001
<CH2 processing specification
U0\
MOV
K0
G4002
<CH2 auto command wait time setting >
U0\
MOV
K0
G4010
<CH2 processing result monitor switch setting>
U0\
MOV
K0
G4011
RST
M1000
Set
parameters
END
>
>
>
>