6. HOW TO COMMUNICATE WITH ID TAGS
6 - 69
(2) Program example
Module status
M1150
Read
Module
Status
command
<CH1 communication specification
U0\
MOV
G40
D1150
CH1 module
status
<CH1 communication specification
U0\
MOV
G42
D1151
CH1
processing
result
monitor
<CH1 ID tag UID
U0\
BMOV
G90
D1152
K4
CH1 ID
tag UID
<CH2 communication specification
U0\
MOV
G4040
D1156
CH2 module
status
<CH2 communication specification
U0\
MOV
G4042
D1157
CH2
processing
result
monitor
<CH2 ID tag UID
U0\
BMOV
G4090
D1158
K4
CH2 ID
tag UID
RST
M1150
Read
Module
Status
command
END