6. HOW TO COMMUNICATE WITH ID TAGS
6.4.5 Clear bit
6 - 34
The Clear Bit program is a program for clearing the specified bits of the data of an ID
tag to "0".
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Command code specification
U0 \ G0
area (CH1)
Head address specification
U0 \ G3
area (CH1)
Number of processed points
U0 \ G4
specification area (CH1)
(b) Devices used by user
1. External inputs (commands/data)
Device
M1040
Clear Bit of ID Tag command
M1041
Clear Bit of ID Tag result reception
M1042
Cancel Clear Bit of ID Tag command
D3410 to D3411
Specifies the data of the ID Tag for which bits are to be cleared.
2. External outputs (verification)
Device
M1043
Normal completion during Clear Bit of ID Tag
M1044
Module error during Clear Bit of ID Tag
M1045
ID communication complete during Clear Bit of ID Tag
D1040
Error details storage during Clear Bit of ID Tag
Buffer Memory Name
Application
Application
Setting Contents
H3 (Clear bit)
K10 (Address: 10)
K4 (4 bytes)
6 - 34