4. SETUP AND PROCEDURES PRIOR TO OPERATION
4 - 9
(b) Switch 2 (TEST mode setting)
For TEST mode, refer to Section 5.1.3.
1. Enable Y contact test request (b0)
Enables/Disables testing using the Y contact (Programmable controller CPU
output signal Y15: ON) in RUN mode.
0 (OFF): Enable
1 (ON): Disable
2. Enable channel 1 TEST mode (b1)
Enables/Disables the test switch "TEST" setting and "Enable Y contact TEST
request" setting for channel 1.
0 (OFF): Enable
1 (ON): Disable
3. Enable channel 2 TEST mode (b2)
Enables/Disables the test switch "TEST" setting and "Enable Y contact TEST
request" setting for channel 2.
0 (OFF): Enable
1 (ON): Disable
(2) Operation procedure
The switches are set from the GX Developer IO assignment setting screen.
(a) IO assignment setting screen
Set the following settings in the slot where the RFID interface module is
mounted. While "Type" is required, set all other items as necessary.
(b) Intelligent function module switch setting screen
Type
: Select "Intelli".
Model
: Enter the module model.
No. of points
: Select 32 points.
Head XY
: Enter the head IO number of the
RFID interface module.
Selected settings : Invalid with the RFID interface
module. Setting is not required.
Detailed settings
: Specify the control CPU of the
RFID interface module. "Output
mode at time of error" and "CPU
operation mode at time of H/W
error" are invalid with the RFID
interface module. Setting is not
required.
Click on "Switch settings" on the IO assignment
setting screen to display the screen below, and set
switches 1 to 5.
The settings can be simply set by entering the
settings in hexadecimal format. Change the input form
to hexadecimal and enter the settings.