6. HOW TO COMMUNICATE WITH ID TAGS
Initialize output devices
ID instruction execution
6 - 60
(2) Program example
M1120
Write with
Error
Correction
command
M1120
X0
X2
Write with
Module
CH1 ID
Error
ready
communication
Correction
complete
command
X3
X4
X5
CH1 ID
CH1 error
CH.1 ID
instruction
detection
-BUSY
complete
RST
M1123
Normal
completion
during Write
with Error
Correction
RST
M1124
Module error
during Write
with Error
Correction
RST
M1125
ID
communication
complete
during Write
with Error
Correction
MOV
K0
D1120
Error details
storage
during Write
with Error
Correction
<Command code specification
U0\
MOV
H0B
G0
<Head address specification
U0\
MOV
K10
G3
<Number of processed points specification >
U0\
MOV
K8
G4
<Write to data storage area
U0\
BMOV
D2300
G100
K4
Write
data
SET
Y14
CH1 ID
instruction
execution
request
RST
M1120
Write with
Error
Correction
command
6 - 60
>
>
>