6. HOW TO COMMUNICATE WITH ID TAGS
6.4.8 Fill data
6 - 44
The Fill Data program is a program for initializing the data of an ID tag with specified
data.
(1) Program conditions
(a) Setting contents
Intelligent Function
Module Device
Address
Command code specification
U0 \ G0
area (CH1)
Head
U0 \ G3
area (CH1)
Number of processed points
U0 \ G4
specification area (CH1)
U0 \ G100
Data storage area (CH1)
(b) Devices used by user
1. External inputs (commands/data)
Device
M1070
Fill Data of ID Tag command
M1071
Fill Data of ID Tag result reception
M1072
Cancel Fill Data of ID Tag command
2. External outputs (verification)
Device
M1073
Normal completion during Fill Data of ID Tag
M1074
Module error during Fill Data of ID Tag
M1075
ID communication complete during Fill Data of ID Tag
D1070
Error details storage during Fill Data of ID Tag
Buffer Memory Name
address
specification
Application
Application
Setting Contents
H6 (Fill Data)
K0 (Address: 0)
K0 (All data specified)
K0 (Fill data: 0)