6. HOW TO COMMUNICATE WITH ID TAGS
6.4.1 Set parameters
6 - 23
The Set Parameters program is a program for setting parameters such as the
communication specification or processing specification.
(1) Program conditions
(a) Parameter setting contents
Intelligent Function
Module Device
Address
Communication specification
U0 \ G1
area (CH1)
Processing specification area
U0 \ G2
(CH1)
Auto command wait time
U0 \ G10
setting area (CH1)
Processing result monitor
U0 \ G11
switch setting area (CH1)
Communication specification
U0 \ G4001
area (CH2)
Processing specification area
U0 \ G4002
(CH2)
Auto command wait time
U0 \ G4010
setting area (CH2)
Processing result monitor
U0 \ G4011
switch setting area (CH2)
(b) Devices used by user
1. External inputs (commands)
Device
M1000
Set parameters command
Buffer Memory Name
Application
Setting Contents
K0 (Trigger)
K0 (Data storage order:
Upper –> Lower
Calculation method: Addition
Calculation/Verification:
Calculation)
K0 (Continuously executes the ID
instruction until there is a
response from the ID tag)
K0 [Stores the communication time
in the processing result monitor
storage area (U0 \ G42)]
K0 (Trigger)
K0 (Data storage order:
Upper –> Lower
Calculation method: Addition
Calculation/Verification:
Calculation)
K0 (Continuously executes the ID
instruction until there is a
response from the ID tag)
K0 [Stores the communication time
in the processing result monitor
storage area (U0 \ G4042)]